Installation
• To manually operate the new valve, four 2.5mm socket
allen screws must be removed, the valve coil removed,
and the valve globe rotated with pliers.
• The valve coil has an indicator
line showing valve position.
Ensure valve is reassembled in
the same position.
Remove four 2.5mm coil retaining allen
screws.
Remove the coil from the valve body.
Using pliers, turn the valve body key to
the vertical position to open valve.
Reassemble in reverse order.
1
2
3
Drain Valve Manual Operation
Fig. 7
7
Summary of Contents for MD2000-VHR
Page 32: ...12 11 10 14 13 9 8 7 6 5 4 1 2 3 Wash Pump Motor 24...
Page 38: ...Door Lock 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 30...
Page 48: ...5 6 7 9 3 4 1 2 8 11 10 Tracks 40...
Page 50: ...Dish Racks 2 1 42...
Page 52: ...Electrical Schematic 44...