![Moyer Diebel MD-1000HT Installation Manual With Service Replacement Parts Download Page 29](http://html1.mh-extra.com/html/moyer-diebel/md-1000ht/md-1000ht_installation-manual-with-service-replacement-parts_1842812029.webp)
23
The Troubleshooter
In order to find the cause of a breakdown or abnormal operating condition in your dishwasher please
ensure that:
1. All switches are ON
2. Drain overflow tube is in place and seated
3. Wash pipe and rinse nozzles are clean
4. Spray arms are in their proper positions
5. Round screen is properly positioned
6. Detergent, sanitizer and rinse additive dispensers are adequately filled
8. Doors are fully closed.
That wasn't it? Check for a solution below:
PROBLEM
CAUSE
SOLUTION
Cycle will not start
Door not closed ........................... Make sure doors are fully closed
Door safety switch faulty ............. Contact your service agency
Main switch off ............................. Check disconnect
Low or no water
Main water supply is turned off ... Turn on house water supply
Drain/overflow tube is not
in place and seated ..................... Clean, replace and seat drain tube
..................................................... as needed.
Faulty fill valve ............................. Contact your chemcial supplier.
Continuous water filling
Fill valve will not close ................. Clean or replace
Motor not running
Defective contactor ..................... Contact your servicer
Defective motor ........................... Contact your servicer
Wash tank water temperature ..................................................... Incoming water temperature
is low when in use
..................................................... at machine too low
..................................................... Raise temperature to 140°F/60°C
Defective thermometer ................ Check or replace
Defective solenoid valve ............. Check or replace
Arms not rotating
Rinse nozzles not clean .............. Clean
Bearings worn .............................. Replace
Water supply pressure low ......... Check incoming water pressure
Insufficient pumped spray
Clogged intake screen ............... Clean
pressure
Clogged spray pipe ..................... Clean
Low water level in tank ................ Check drain and overflow tube, timer may
..................................................... need adjustment, contact servicer
Defective pump seal .................... Contact service agent
Insufficient rinse or no
Faulty pressure regulating valve . Clean or replace
rinse
Improper setting on pressure
regulating valve ........................... Set static pressure to 35 psi
Clogged rinse nozzle and/or
pipe .............................................. Clean with paper clip/delime
Improper water line size .............. Have installer change to proper size 3/4" NPT
MD-1000HT • The Trounbleshooter
Summary of Contents for MD-1000HT
Page 13: ...7 This Page Intentionally Left Blank Blank Page ...
Page 31: ...25 Model MD 1000LT Installation Guide MD 1000LT Installation Guide ...
Page 40: ...34 This Page Intentionally Left Blank Blank Page ...
Page 48: ...42 Blank Page This Page Intentionally Left Blank ...
Page 71: ...65 Service Replacement Parts Dishrack track assembly ...
Page 73: ...67 Service Replacement Parts Sprayarm assembly ...
Page 74: ...68 Blank Page This page intentionally left blank ...
Page 76: ...70 This page intentionally left blank Blank Page ...
Page 78: ...72 Blank Page This page intentionally left blank ...
Page 79: ...Electrical schematics Timer cycle chart High temperature model 73 ...
Page 80: ...Electrical schematics Timer cycle chart Low temperature model 74 ...