6
1. Locate the built-in stainless steel booster on the left-side of the dishwasher.
2. Connect a 3/4” NPT hot water supply to the dishwasher at the line strainer.
Installation Guide _____________
;
Water Connection MD-1000HT
Dishwasher temperature
and water pressure requirements:
140°F/60°C minimum) for 40° F/22° C rise booster
(35 psi/241 KPa static pressure)
7-10 psi/63-69Kpa flow pressure
(110°F/43°C minimum) for 70° F/39° C rise booster
(35 psi/241 KPa static pressure)
7-10 psi/48-69Kpa flow pressure
Note:
The existing hot water supply lines to the dishwasher must be 3/4" NPT or larger. To the best of
your ability inspect, and verify that all supply piping meets the 3/4" NPT requirement.
MD-1000HT • Water Connection
Note:
The following components
are not required
for proper dishwasher operation, but are
highly recommended
, because they make servicing of the dishwasher much faster.
Install the following components (not supplied) in the hot water supply line:
1) 3/4” or larger water shut-off valve near the machine in the water supply line.
2) ASSE 1010 Water hammer arrestor upstream from the shut-off valve.
3) Pressure gauge 0-60 PSI minimum downstream from the PRV.
4) Temperature gauge 0-180°F/82°C (not supplied) downstream from the gauge.
Note:
The installing plumber must connect a water supply line to the dishwasher that is equal to or
greater than 3/4" NPT in size and a 3/4" pressure regulating valve, PRV (not supplied).
Summary of Contents for MD-1000HT
Page 13: ...7 This Page Intentionally Left Blank Blank Page ...
Page 31: ...25 Model MD 1000LT Installation Guide MD 1000LT Installation Guide ...
Page 40: ...34 This Page Intentionally Left Blank Blank Page ...
Page 48: ...42 Blank Page This Page Intentionally Left Blank ...
Page 71: ...65 Service Replacement Parts Dishrack track assembly ...
Page 73: ...67 Service Replacement Parts Sprayarm assembly ...
Page 74: ...68 Blank Page This page intentionally left blank ...
Page 76: ...70 This page intentionally left blank Blank Page ...
Page 78: ...72 Blank Page This page intentionally left blank ...
Page 79: ...Electrical schematics Timer cycle chart High temperature model 73 ...
Page 80: ...Electrical schematics Timer cycle chart Low temperature model 74 ...