Installation
Priming the Chemical Injectors and Approximate Chemical Settings
Each chemical injector can be adjusted using its prime button and concentration adjusting screw.
These controls are located on the right side of the control box located in the lower compartment of the
glasswasher. The white injector rotors are visible through the control box window.
ALL OF THE CHEMICAL SETTINGS BELOW ARE APPROXIMATIONS.
CONSULT A QUALIFIED CHEMICAL REPRESENTATIVE TRAINED IN THE USE OF THE TEST
EQUIPMENT REQUIRED FOR TAKING SAMPLES AND PERFORMING ADJUSTMENTS.
1.
Priming the Pumps:
Make sure the proper chemical pick-up tube is in its supply container, then
push and hold the prime button until the detergent, sanitizer and rinse-aid feed tubes are full of
chemical. Release the Prime button.
2.
Approximate Chemical Settings:
The approximate chemical volume dispensed by the chemical injectors can be
determined by counting the number of revolutions of the injector rotor.
Detergent - 1 revolution in 1-second of the detergent pump rotor ~ 0.35% concentration.
Sanitizer - 1 revolution in 5-seconds ~ 12.5 ppm of Iodophor or 50 ppm of chlorine.
Rinse-aid - 1 revolution in 8-seconds ~ the median volume recommended.
Turn the Injector Concentration screws clockwise to increase or counter-clockwise
to decrease the volume of dispensed chemical.
3.
The detergent chemical setting must be performed when the hot-water fill solenoid valve is open.
The hot-water valve is open when the power switch is in the ON position during initial fill and when
the detergent tank float assembly calls for hot water
The sanitizer and the rinse-aid setting can be performed whenever the cold-water fill solenoid valve
is open. The cold-water fill valve is open whenever the glasswasher power switch is ON and
the conveyor is turning. A separate rinse-aid is not needed when Iodophor is used as a sanitizer.
Turn the Injector Concentration Screw fully counter-clockwise until the rinse-aid injector rotor stops
turning.
+
-
Push to prime
Turn CW to in)
CCW to decrease (-)
DET
SAN
R/A
Chemical Injector Prime and Concentration Controls
Detergent
Sanitizer
Rinse-aid
Rotor
Summary of Contents for DFM7
Page 22: ...14 This Page Intentionally Left Blank Blank Page...
Page 24: ...16 1 3 2 4 5 7 9 10 8 11 8 8 8 16 5 5 10 12 8 8 13 14 6 15 8 18 17 19 20 Base Assembly...
Page 26: ...18 1 2 3 3 4 5 6 7 Conveyor Guides Curtains...
Page 30: ...22 1 2 3 4 5 6 9 8 7 11 10 Conveyor Stop Switch...
Page 32: ...24 1 3 2 4 6 5 5 7 8 Drive Motor Assembly...
Page 34: ...26 7 8 9 2 1 6 5 4 3 2 1 Vacuum Breaker Assembly...
Page 36: ...28 2 1 6 7 7 7 9 11 12 10 10 8 3 4 5 Wash Pump and Piping...
Page 40: ...32 8 1 2 3 2 2 2 2 4 6 1 5 7 11 1 9 10 10 13 12 15 14 Sanitizer Plumbing...
Page 46: ...38 Options And Accessories 1 3 2 4 5 6 5 7 8 9 10 12 11 13 14...
Page 48: ...40 Electric Schematic...
Page 49: ...41 Blank Page This Page Intentionally Left Blank...
Page 50: ...42...