![Moyer Diebel DFM7 Installation Manual Download Page 12](http://html1.mh-extra.com/html/moyer-diebel/dfm7/dfm7_installation-manual_1842806012.webp)
4
Installation
Installation
(continued)
Chemicals
Glassware cleaning chemicals
1. A qualified chemical supplier should supply liquid detergent, sanitizer and rinse-aid for the
glasswasher. The glasswasher manufacturer does not sell glassware washing chemicals.
2. A chemical's formulation and strength vary depending on the chemical supplier; therefore,
the specifications given below are approximations only.
3. The glasswasher has 3 built-in chemical dispensing pumps for
Detergent - Use a commercial grade non-chlorinated detergent specifically made for glasswashers.
The recommended concentration of detergent should be .35%
Sanitizer - 2 types of sanitizer may be used.
(5.25%) Sodium hypochlorite
(chlorine bleach)
to provide a minimum concentration of
50 ppm in the final rinse. The 50 ppm concentration must be checked using test strips
to make sure the proper concentration is maintained.
Iodophor
(Iodine formulated with a rinse agent),
to provide a minimum concentration of
12.5ppm in the final rinse. The 12.5 ppm concentration must be checked using
test strips to make sure the proper concentration is maintained.
Rinse-aid
Consult your chemical supplier for the proper type of rinse-aid to use in the glasswasher.
Installing chemical supply containers and chemical pick-up tubes
1. There is enough space inside the lower compartment to hold
3 one gallon containers for detergent, sanitizer, and rinse-aid.
The contents of each container must be marked clearly.
2. The glasswasher comes equipped with 3 gray tubes, called
stiffener tubes, and tubing for each chemical pump.
The tubing inserted in the chemical container has a strainer.
3. The outlet tubes from the supply containers to the chemical
pumps are marked with color-coded labels, they are:
RED -
Detergent
(DET)
CLEAR -
Sanitizer
(SAN)
BLUE -
Rinse-aid
(R/A)
4. Pull the stiffener tubes and chemical tubing forward and
out of the compartment. Make sure the tubing is not
tangled or kinked.
5. Insert the stiffener tube and pick-up tubing into its
container and stow the supply containers in the lower
compartment as shown to the right.
RED
CLEAR
BLUE
SANITIZER
DETERGENT
RINSE
DET
SAN
R/A
DET
SAN
R/A
Summary of Contents for DFM7
Page 22: ...14 This Page Intentionally Left Blank Blank Page...
Page 24: ...16 1 3 2 4 5 7 9 10 8 11 8 8 8 16 5 5 10 12 8 8 13 14 6 15 8 18 17 19 20 Base Assembly...
Page 26: ...18 1 2 3 3 4 5 6 7 Conveyor Guides Curtains...
Page 30: ...22 1 2 3 4 5 6 9 8 7 11 10 Conveyor Stop Switch...
Page 32: ...24 1 3 2 4 6 5 5 7 8 Drive Motor Assembly...
Page 34: ...26 7 8 9 2 1 6 5 4 3 2 1 Vacuum Breaker Assembly...
Page 36: ...28 2 1 6 7 7 7 9 11 12 10 10 8 3 4 5 Wash Pump and Piping...
Page 40: ...32 8 1 2 3 2 2 2 2 4 6 1 5 7 11 1 9 10 10 13 12 15 14 Sanitizer Plumbing...
Page 46: ...38 Options And Accessories 1 3 2 4 5 6 5 7 8 9 10 12 11 13 14...
Page 48: ...40 Electric Schematic...
Page 49: ...41 Blank Page This Page Intentionally Left Blank...
Page 50: ...42...