![Moxa Technologies VPort 364 Series Quick Installation Manual Download Page 12](http://html.mh-extra.com/html/moxa-technologies/vport-364-series/vport-364-series_quick-installation-manual_1842261012.webp)
- 12 -
NOTE
Test the screw head and shank size by inserting the screw into
one of the keyhole shaped apertures of the wall mounting plates,
before it is screwed into the wall.
STEP 3:
Once the screws are fixed in the wall, insert the four screw heads through
the large parts of the keyhole-shaped apertures, and then slide the VPort
364 downwards, as indicated below. Tighten the four screws for added
stability.
Wiring Requirements
WARNING
Safety First!
Be sure to disconnect the power cord before installing and/or
wiring your Moxa VPort 364.
Calculate the maximum possible current in each power wire and
common wire. Observe all electrical codes dictating the
maximum allowable current for each wire size.
If the current goes above the maximum ratings, the wiring could
overheat, causing serious damage to your equipment.
You should also pay attention to the following items:
•
Use separate paths to route wiring for power and devices. If power
wiring and device wiring paths must cross, make sure the wires are
perpendicular at the intersection point.
NOTE
Do not run signal or communications wiring and power wiring in
the same wire conduit. To avoid interference, wires with different
signal characteristics should be routed separately.
•
You can use the type of signal transmitted through a wire to
determine which wires should be kept separate. The rule of thumb is
that wiring that shares similar electrical characteristics can be
bundled together.
•
Keep input wiring and output wiring separated.
•
It is strongly advised that you label wiring to all devices in the system.