Moxa Industrial Smart Ethernet Switch
Quick Start Guide
2-9
Maximum Login Users for HTTP+HTTPS
Setting
Description
Factory Default
Integer (1 to 10)
Sets the maximum number of users who can log in to HTTP and
HTTPS simultaneously.
5
Auto Logout Setting (min)
Setting
Description
Factory Default
Integer (0 to 1440)
Sets the web auto logout period.
(Enter 0 to disable this function.)
5
NOTE: Press Apply once all settings have been properly set to activate the function.
Port Mirror Instructions
The following screenshot gives an overview of the port mirror settings page and details of each parameter.
Port Mirror
Setting
Description
Monitored Port
Select which ports will be monitored.
Sniffer Mode
Select one of the following three watch direction options:
•
RX: Select this option to monitor only those data packets coming into the Moxa
switch’s port.
•
TX: Select this option to monitor only those data packets being sent out through the
Moxa switch’s port.
•
TX/RX: Select this option to monitor data packets both coming into, and being sent
out through, the Moxa switch’s port.
Mirror Port
Select the number of the port that will be used to monitor the activity of the monitored
port.
NOTE: Press Apply once all settings have been properly set to activate the function.