![Moxa Technologies NPort W2150Plus Series User Manual Download Page 39](http://html1.mh-extra.com/html/moxa-technologies/nport-w2150plus-series/nport-w2150plus-series_user-manual_1842600039.webp)
NPort W2150/2250 Plus Series User’s Manual
Web Console: Basic Settings
5-5
Local Time
Default
Options
Date (yy:mm:dd), Time (hh:mm:ss)
Description
The NPort has a built-in real-time clock that allows you to add time information
to functions such as the automatic warning e-mail or SNMP trap. This field
shows the current time according to the NPort’s built-in real-time clock. This is
not a live field, so you will need to refresh the browser to get an updated
reading.
Click
[Modify]
to adjust the real-time clock. Make sure that you first select the
correct time zone. The real-time clock will be updated immediately, with no
need to restart the NPort.
ATTENTION
There is a risk of explosion if the real-time clock battery is replaced incorrectly!
The real time clock is powered by a lithium battery. We strongly recommend that you obtain
assistance from a Moxa support engineer before replacing the battery. Please contact the Moxa
RMA service team if you need to change the battery.
Time Server
Default
Options
IP address or domain name (e.g., “192.168.1.1” or “time.nist.gov”)
Description
This optional field specifies your time server’s IP address or domain name, if a
time server is used in your network. The NPort supports SNTP (RFC-1769) for
automatic time calibration. The device server will request time information
from the specified time server every 10 minutes.