Female DB9 to Male DB25 

 

ATEX and IECEx Information 

1.

 

Certificate number: DEMKO 07 ATEX 0690059x 

2.

 

Ambient range (-

40°C ≤ Tamb ≤ 75°C)

 

3.

 

Certification string (Ex nA IIC T3) 

4.

 

Standards covered (EN60079-0:2006, EN60079-15:2005, IECEx UL 
13.0023X, IEC 60079-0 Ed. 6, IEC 60079-15 Ed. 4) 

5.

 

Conditions of safe usage: 

The Ethernet Communication Devices are to be mounted in an IP54 
enclosure and used in an area with a pollution degree of not more 
than 2, as defined by IEC 60664-1. 

A 4-mm

2

 conductor must be used when a connection to the external 

grounding screw is utilized. 

Conductors suitable for use in an ambient temperature of 114°C must 
be used for the Power Supply Terminal. 

Provisions shall be made, either in the apparatus or external to the 
apparatus, to prevent the rated voltage to exceed the transient 
disturbance by more than 40%. 

 

Summary of Contents for NPort IA 5250 series

Page 1: ...oxa Americas Toll free 1 888 669 2872 Tel 1 714 528 6777 Fax 1 714 528 6778 Moxa China Shanghai office Toll free 800 820 5036 Tel 86 21 5258 9955 Fax 86 21 5258 5505 Moxa Europe Tel 49 89 3 70 03 99 0 Fax 49 89 3 70 03 99 99 Moxa Asia Pacific Tel 886 2 8919 1230 Fax 886 2 8919 1231 Moxa India Tel 91 80 4172 9088 Fax 91 80 4132 1045 2016 Moxa Inc All rights reserved ...

Page 2: ...s come with a compact and rugged DIN rail mountable casing Package Checklist Before installing NPort IA device servers verify that the package contains the following items 1 NPort IA series device server Documentation and software CD NPort IA series quick installation guide Optional Accessories DR 4524 5W 2A DIN rail 24 VDC power supply with universal 85 to 264 VAC input DR 75 24 75W 3 2A DIN rail...

Page 3: ...nd the NPort IA is booting up Blinking Indicates an IP conflict the DHCP or BOOTP server did not respond properly or a relay output occurred Green Steady on Power is on and the NPort IA is functioning normally Blinking The device server has been located by the Administrator s Location function Off Power is off or a power error condition exists Ethernet Orange 10 Mbps Ethernet connection Green 100 ...

Page 4: ...N rail or mounted on a wall The two sliders on the NPort IA s rear panel serve a dual purpose For wall mounting both sliders should be extended For DIN rail mounting start with one slider pushed in and the other slider extended After attaching the NPort IA on the DIN rail push the extended slider in to lock the device server to the rail The two placement options are illustrated in the accompanying...

Page 5: ...ND GND 6 DSR 7 RTS 8 CTS 9 4W 2W RS 485 RS 422 Terminal Block Pinouts PIN RS 485 2W RS 422 RS 485 4W 1 TxD B 2 TxD A 3 Data B RxD B 4 Data A RxD A 5 GND Four cables are available as optional accessories that can be used to connect the NPort IA to RS 232 serial devices For your convenience we show precise cable wiring diagrams for each of the two cables Female DB9 to Male DB9 ...

Page 6: ...t Communication Devices are to be mounted in an IP54 enclosure and used in an area with a pollution degree of not more than 2 as defined by IEC 60664 1 A 4 mm2 conductor must be used when a connection to the external grounding screw is utilized Conductors suitable for use in an ambient temperature of 114 C must be used for the Power Supply Terminal Provisions shall be made either in the apparatus ...

Reviews: