background image

 

 

P/N: 1802045001011 

*1802045001011* 

ioThinx 4500 (45M) Module 

Series   

Quick Installation Guide 

 

Version 1.1, July 2019 

Technical Support Contact Information 

www.moxa.com/support 

Moxa Americas: 
Toll-free: 1-888-669-2872 
Tel:  1-714-528-6777 
Fax:  1-714-528-6778 

Moxa China (Shanghai office): 
Toll-free: 800-820-5036 
Tel:  +86-21-5258-9955 
Fax:  +86-21-5258-5505 

Moxa Europe: 
Tel:  +49-89-3 70 03 99-0 
Fax:  +49-89-3 70 03 99-99 

Moxa Asia-Pacific: 
Tel:  +886-2-8919-1230 
Fax:  +886-2-8919-1231 

Moxa India: 
Tel:  +91-80-4172-9088 
Fax:  +91-80-4132-1045 

 

 

 

 

 

 

 2019 Moxa Inc. All rights reserved. 

 

 

Summary of Contents for ioThinx 4500 Series

Page 1: ... Moxa Americas Toll free 1 888 669 2872 Tel 1 714 528 6777 Fax 1 714 528 6778 Moxa China Shanghai office Toll free 800 820 5036 Tel 86 21 5258 9955 Fax 86 21 5258 5505 Moxa Europe Tel 49 89 3 70 03 99 0 Fax 49 89 3 70 03 99 99 Moxa Asia Pacific Tel 886 2 8919 1230 Fax 886 2 8919 1231 Moxa India Tel 91 80 4172 9088 Fax 91 80 4132 1045 2019 Moxa Inc All rights reserved ...

Page 2: ...e head CPU module making sure that the upper and lower rails are hooked together Step 2 Align the 45M module side by side with the head CPU module and then push the 45M module until it touches the DIN rail Next apply more force until the module clips to the DIN rail NOTE After the module is firmly attached to the DIN rail the module connections to the internal bus will be established ...

Page 3: ...e lower part of the module Step 2 Push the top of the release tab to latch it and then pull the module out NOTE Electrical connections for the internal bus will be disconnected when removing the 45M module WARNING Be sure the power is off before removing modules to avoid damaging the equipment ...

Page 4: ...stallation Before installing the device make sure there is enough space between the device and nearby items walls other devices etc to ensure proper heat dissipation To ensure that the device works properly we suggest reserving the amount of space indicated in the adjacent figure CAUTION DO NOT install the device vertically If the device is installed vertically the fanless heat dissipation design ...

Page 5: ... 45MR 2600 2601 2606 must use an external power supply for field power Operating Temperature Standard Models 20 to 60 C 4 to 140 F Wide Temp Models 40 to 75 C 40 to 167 F Storage Temperature 40 to 85 C 40 to 185 F Attention 1 This device is only for indoor use in environments with pollution degree 2 2 The 45M has a ground pin on the back of the device For surge protection connect the DIN rail to e...

Reviews: