Connection Cable and Cable Wiring
Industio
CP-114 User's Manual
5-3
Type 2: To connect Industio CP-114 Series to a DCE device.
Modem
or any DCE Device
CP-114
CP-114
DCE
Device
DB9 Male
DB25 Female
RxD
2 2 RxD
TxD
3 3 TxD
CTS
8 4 CTS
RTS
7 5 RTS
DTR
4 6 DTR
DSR 6
20
DSR
GND
5 7 GND
DCD
1 8 DCD
Type 3: To connect Industio CP-114 Series to a DTE with 3-pin wiring.
If the [
Hardware flow control
] feature is set to “
ON
”, you must loop back (or short) the
RTS with CTS and the DSR with DTR, DCD on the MOXA site.
If [
Hardware flow control
] feature is set to “
OFF
”, you could just leave RTS, CTS,
DSR, DTR, DCD open, ignoring the connection indicated in dash-lines.
PC COM2 port, Serial Printer,
Terminal, or any DTE Device
CP-114
CP-114
DTE
Device
DB9 Male
DB25 Male
TxD 3
2
TxD
RxD 2
3
RxD
GND 5
7
GND
RTS 7
4
RTS
CTS 8
5
CTS
DTR 4
20
DTR
DSR 6
6
DSR
DCD 1
8
DCD
PC COM2 port, Serial Printer,
Terminal, or any DTE device
CP-114
CP-114
DTE Device
DB9 Male
DB9 Male
TxD 3
3
TxD
RxD 2
2
RxD
GND 5
5
GND
RTS 7
7
RTS
CTS 8
8
CTS
DSR 6
6
DSR
DTR 4
4
DTR
DCD 1
1
DCD