3-4
Industio
CP-114 User's Manual
Rx FIFO trigger levels, at 1, 4, 8 or 14 bytes, are available, and the default value is 14
bytes.
!
Tx FIFO Size
Tx FIFO sizes from 1 to 16 bytes are available, and the default value is 16 bytes.
8.
Click [
OK
] in the “Port #” and the “Property” dialog boxes to go back to the “Moxa
Smartio/Industio Configuration Panel” dialog box.
Note !
If you need to install more than one board, click [
Add
] and repeat steps
6
to
8
to
configure another board. Up to four Industio CP-114 Series boards can be installed
in a system.
Click [
OK
] to finish the configuration.
9.
When configuration is done, click on [
Close
] button in the “Network Settings” dialog box.
10.
Restart Windows NT system. The latest configuration will not take effect unless the system
restarts.
Note !
The latest configuration will not take effect unless the system restarts.
11.
Once the system restarts, you may check the event log issued by the MOXA driver to see if the
ports of the board are initialized successfully.
!
Enter the [
Administrative
]
group, click on the [
Event Viewer
]
icon and select [
Log
] and
[
System
] to check a message similar to
“MOXA CP-114, with first serial port COM3, has
been enabled”
for each configured board.
!
If an error message similar to
“Cannot find any configured MOXA CP-114 board!”
appears, refer to the “Troubleshooting” chapter for solutions.