Industio
CP-114 User's Manual
2-1
2
2
2
Hardware Installation
The
installation of the Industio CP-114 Series consists of hardware and software installation. The
respective sections of the operating systems in the next chapter deal with the software installation.
The hardware installation is detailed in this chapter.
First Thing to Do: Interface Settings
Before installing the board into the slot, you should set all the jumpers to what you want.
The
default (factory) settings: Port 1, Port 2, Port 3 and Port 4 RS-485, Automatic Data Direction
Control mode, no Termination Resistor, indicated as *
.
!
JP5/6 Interface Selection Jumper for Port 1/2:
Left *
Set the port interface to RS-422/RS-485.
Right
Set the port interface to RS-232.
!
S1 RS-422/485 Selection Switch for Port 1/2/3/4:
ON *
Set the port interface to RS-485.
OFF
Set the port interface to RS-422.
JP1
JP2
JP4
JP3
Industio
CP-114 Series Board
O
N
1 2 3 4
O
N
1 2 3 4
RS-232
RS-422
RS-485
JP5
RS-232
RS-422
RS-485
JP6
By RTS RS-422
SW2 SW1
AUTO RS-485
JP1/2/4/3:Termination Resistor Jumper for Port 1/2/4/3
JP5:Interface selection Jumper for Port 1
JP6:Interface selection Jumper for Port 2
SW1: RS-422/RS-485 Selection Switch for Port 1/2/3/4
SW2: Data Mode Switch for Port 1/2/3/4
Summary of Contents for Industio CP-114 Series CP-114 Series
Page 6: ......
Page 10: ...1 4 Industio CP 114 User s Manual...
Page 20: ...Industio CP 114 User s Manual 3 8...
Page 48: ......