Pinouts and Cable Wiring
l
l
Appendix A
43
Type 3:
To connect C114HI to a DTE with 3-pin wiring.
If [Hardware flow control] feature is set to "ON", user must loop back (or short)
the RTS with CTS and DSR with DTR, DCD on MOXA site.
C114HI
DTE
C114HI
DTE
DB-9 Male
DB-25 Male
DB-9 Male
DB-9 Male
3
TxD
3
RxD
3
TxD
2
RxD
2
RxD
2
TxD
2
RxD
3
TxD
5
GND
7
GND
5
GND
5
GND
7
RTS
7
RTS
8
CTS
8
CTS
6
DSR
6
DSR
4
DTR
4
DTR
1
DCD
1
DCD
If [Hardware flow control] feature is set to "OFF", users could just leave RTS,
CTS, DSR, DTR, DCD open.
C114HI
DTE
C114HI
DTE
DB-9 Male
DB-25 Male
DB-9 Male
DB-9 Male
3
TxD
3
RxD
3
TxD
2
RxD
2
RxD
2
TxD
2
RxD
3
TxD
5
GND
7
GND
5
GND
5
GND
7
RTS
7
RTS
8
CTS
8
CTS
6
DSR
6
DSR
4
DTR
4
DTR
1
DCD
1
DCD