Chapter 4
l
l
For Windows NT Users
19
checking the following items:
-
Plug in the board(s) properly.
-
Inspect carefully on the settings of I/O address for each board installed.
-
Sometimes slot for plugging board is malfunctioned.
In this case, please try other slots until good one is found.
-
The board might be defective.
-
For "quick installation" users, make sure the jumper JP1 is always short and
the additional I/O address 0xA700 is not occupied by other devices.
If some other device use 0xA700 at the same time, I/O address conflict occurs.
For example, a
partially decoded
device is using I/O address
0x300
. This will
cause conflict with 0xA700, a
fully decoded
I/O address. In this case, either find
out the other device causing conflict and change its I/O address if possible. Or
use normal installation procedure for C114HI board, instead, to avoid conflict.
2. The
C114HI's
software
and
hardware
configuration
mismatch
(CAP=0xXXXX)!
-
To avoid this, please check the board settings of the software configuration
via entering [Control Panel] group, then [Network] icon, then [Adapters]
folder and then [MOXA C102/C104/C168 Configuration Panel] for each
board installed, then shut down the system and run Io-irq.exe to check the
board settings of the hardware configuration. Make sure both are same.
-
The board might be defective.
Summary of Contents for Industio C114HI
Page 1: ...C114HI 3 in 1 RS 232 422 485 Industrial Serial Board Apr 1998 2nd Edition All Rights Reserved...
Page 6: ......
Page 10: ...Introduction l l Chapter 1 4...
Page 20: ...Software Installation l l Chapter 3 14...
Page 26: ...For Windows NT Users l l Chapter 4 20...
Page 38: ...For DOS Users l l Chapter 7 32...
Page 42: ...For Windows 3 x Users l l Chapter 8 36...
Page 46: ...Chapter 9 l l RS 232 RS 422 RS 482 Programming 40...