- 9 -
Wiring the Dual Power Inputs
The top two pairs of contacts of the 10-contact terminal block connector
on the AWK-3131A-M12-RCC’s top panel are used for the
AWK-3131A-M12-RCC’s two DC inputs. Top and front views of the
terminal block connector are shown below.
STEP 1:
Insert the negative/positive DC wires into the
V-/V+ terminals.
STEP 2:
To keep the DC wires from pulling loose, use a
small flat-blade screwdriver to tighten the
wire-clamp screws on the front of the terminal
block connector.
STEP 3:
Insert the plastic terminal block connector
prongs into the terminal block receptor, which is
located on the AWK-3131A-M12-RCC’s top
panel.
NOTE
Before connecting the AWK-3131A-M12-RCC to the DC power
inputs, make sure the DC power source voltage is stable.
Wiring the Relay Contact
The AWK-3131A-M12-RCC has one relay output, which consists of the
two contacts of the terminal block on the AWK-3131A-M12-RCC’s top
panel. The two wires attached to the Relay contacts form an open circuit
when a user-configured event, such as the network connection status
change, DI0/1 status change, or power status change, is triggered. If a
user-configured event does not occur, the Relay circuit will be closed.
Wiring the Digital Inputs
The AWK-3131A-M12-RCC has two sets of digital input—DI0 and DI1.
Each DI comprises two contacts of the 10-pin terminal block connector on
the AWK-3131A-M12-RCC’s top panel.
Cable Holder Installation
You can attach the cable holder to the bottom of the
AWK-3131A-M12-RCC. This helps to keep cabling neat and avoid
accidents that result from untidy cables.