- 6 -
Wall Mounting (optional)
For transportation applications that require an EN 50155 certification
report, we strongly recommend the purchase of the optional
AWK-3131A-M12-RCC wall-mounting kit, which has passed EN 50155
testing. This wall-mounting kit is also convenient for other applications
that require mounting the AWK-3131A-M12-RCC to a wall.
STEP 1:
Remove the aluminum
DIN-rail attachment plate
from the
AWK-3131A-M12-RCC, and
then attach the wall mount
plates with M3 screws, as
shown in the adjacent
diagrams.
STEP 2:
Mounting the AWK-3131A-M12-RCC to a wall requires
4 screws. Use the AWK-3131A-M12-RCC device, with
wall mount plates attached, as a guide to mark the
correct locations of the 4 screws. The heads of the
screws should be less than 6.0 mm in diameter, and
the shafts should be less than 3.5 mm in diameter, as
shown in the figure at the right.
Do not screw the screws in all the way—leave a space of about 2 mm to
allow room for sliding the wall mount panel between the wall and the
screws.
NOTE
Test the screw head and shank size by inserting the screw into
one of the keyhole shaped apertures of the Wall Mounting Plates
before it is screwed into the wall.
STEP 3:
Once the screws are fixed into
the wall, insert the four screw
heads through the large opening
of the keyhole-shaped
apertures, and then slide the
AWK-3131A-M12-RCC
downwards, as indicated to the
right. Tighten the three screws
for added stability.