background image

- 8 - 

Arrester Accessories 

 

SA-NMNF-01:

 Surge arrester, N-type (male) to N-type (female) 

 

SA-NFNF-01:

 Surge arrester, N-type (female) to N-type (female) 

Wiring the Redundant Power Inputs 

The top two pairs of contacts of the 10-contact terminal block connector 
on the AWK-3121’s top panel are used for the AWK-3121’s two DC inputs. 
Top and front views of the terminal block connector are shown here. 

 

STEP 1:

 Insert the negative/positive DC wires 

into the V-/V+ terminals. 
 

STEP 2:

 To keep the DC wires from pulling loose, 

use a small flat-blade screwdriver to tighten the 
wire-clamp screws on the front of the terminal 
block connector. 
 

STEP 3:

 Insert the plastic terminal block 

connector prongs into the terminal block 
receptor, which is located on the AWK-3121’s top 
panel. 

 

 

ATTENTION 

Before connecting the AWK-3121 to the DC power inputs, make 
sure the DC power source voltage is stable. 

 

Wiring the Relay Contact 

The AWK-3121 has one relay output, which consists of the two contacts of 
the terminal block on the AWK-3121’s top panel. Refer to the previous 
section for detailed instructions on how to connect the wires to the 
terminal block connector, and how to attach the terminal block connector 
to the terminal block receptor. These relay contacts are used to indicate 
user-configured events. The two wires attached to the Relay contacts 
form an open circuit when a user-configured event is triggered. If a 
user-configured event does not occur, the Relay circuit will be closed. 

Wiring the Digital Inputs 

The AWK-3121 has two sets of digital input—DI1 and DI2. Each DI 
comprises two contacts of the 10-pin terminal block connector on the 
AWK-3121’s top panel. You can refer to the “Wiring the Redundant Power 
Inputs” section for detailed instructions on how to connect the wires to 
the terminal block connector, and how to attach the terminal block 
connector to the terminal block receptor. 

Cable Holder Installation (Optional) 

You can attach the cable holder to the bottom of the AWK-3121. This 
helps to keep cabling neat and avoid accidents that result from untidy 
cables. 

Summary of Contents for AirWorks AWK-3121

Page 1: ...a Americas Toll free 1 888 669 2872 Tel 1 714 528 6777 Fax 1 714 528 6778 Moxa China Shanghai office Toll free 800 820 5036 Tel 86 21 5258 9955 Fax 86 21 5258 5505 Moxa Europe Tel 49 89 3 70 03 99 0 Fax 49 89 3 70 03 99 99 Moxa Asia Pacific Tel 886 2 8919 1230 Fax 886 2 8919 1231 Moxa India Tel 91 80 4172 9088 Fax 91 80 4132 1045 2016 Moxa Inc All rights reserved ...

Page 2: ...or installation in distribution boxes The DIN rail mounting capability wide operating temperature range and IP30 housing with LED indicators make the AWK 3121 a convenient yet reliable solution for any industrial wireless application Package Checklist Moxa s AWK 3121 is shipped with the following items If any of these items is missing or damaged please contact your customer service representative ...

Page 3: ... 5 System LEDs PWR1 PWR2 PoE discontinued starting with HW Rev 2 0 0 FAULT and STATE LEDs 6 LEDs for signal strength 7 WLAN LEDs CLIENT BRIDGE and WLAN LEDs 8 RS 232 console port 9 10 100BaseT X RJ45 Port 10 10M LED 11 100M LED 12 MAIN antenna port 13 AUX antenna port 14 Model name 15 Screw hole for wall mounting kit 16 DIN rail mounting kit ...

Page 4: ... need to reattach the DIN rail attachment plate to the AWK 3121 make sure the stiff metal spring is situated towards the top as shown in the figures below STEP 1 Insert the top of the DIN rail into the slot just below the stiff metal spring STEP 2 The DIN rail attachment unit will snap into place as shown below To remove the AWK 3121 from the DIN rail simply reverse Steps 1 and 2 ...

Page 5: ... in diameter as shown in the figure at the right Do not drive the screws in all the way into the wall leave a space of about 2 mm to allow room for sliding the wall mounting panel between the wall and the screws NOTE Test the screw head and shank size of the screws by inserting the screws into one of the keyhole shaped apertures of the wall mounting plate before attaching the plate to the wall STE...

Page 6: ...ical characteristics can be bundled together Keep input wiring and output wiring separate It is strongly advised that you label wiring to all devices in the system when necessary ATTENTION This product is intended to be supplied by a Listed Power Unit marked Class 2 LPS or Limited Power Source and rated O P 12 to 48 VDC 0 121 to 0 494 A Make sure the external power adapter includes power cords and...

Page 7: ...uipment is recommended to isolate the transient effect and to ensure a stable power input for the AWK Installations with Cable Extended Antennas for Outdoor Applications If the antenna or the AWK device is installed outdoors or in an open air setting proper lightning protection is required to prevent direct lightning strikes on the AWK device In order to prevent coupling currents from nearby light...

Page 8: ...t which consists of the two contacts of the terminal block on the AWK 3121 s top panel Refer to the previous section for detailed instructions on how to connect the wires to the terminal block connector and how to attach the terminal block connector to the terminal block receptor These relay contacts are used to indicate user configured events The two wires attached to the Relay contacts form an o...

Page 9: ...to Ethernet enabled devices Below we show pinouts for both MDI NIC type ports and MDI X HUB Switch type ports MDI Port Pinouts MDI X Port Pinouts 8 pin RJ45 Pin Signal Pin Signal 1 Tx 1 Rx 2 Tx 2 Rx 3 Rx 3 Tx 6 Rx 6 Tx RS 232 Connection The AWK 3121 has one RS 232 8 pin RJ45 console port located on the front panel Use either an RJ45 to DB9 or RJ45 to DB25 cable to connect the Moxa AWK 3121 s conso...

Page 10: ...r ports Refer to the pinout diagram above for details ATEX Information 1 DEMKO certification number 10 ATEX 0902666X 2 Ambient range 40 C Tamb 75 C 3 Certification string Ex nA nL IIC T4 4 Standards covered EN60079 0 2006 EN60079 15 2005 5 The conditions of safe usage a The Ethernet Communication Devices are intended for mounting in an IP54 enclosure and used in an area of not more than pollution ...

Page 11: ...DHCP server Blinking fast at 0 5 second intervals IP address conflict Off No error condition exists STATE Green Red Green System startup is complete and the system is in operation Green Blinking slow at 1 sec intervals The device has been located by Wireless Search Utility Red System is booting up SIGNAL 5 LEDs Green On Signal level for client slave mode only Off BRIDGE Green On WLAN function is i...

Page 12: ...nd Modulation typical DSSS with DBPSK DQPSK CCK OFDM with BPSK QPSK 16QAM 64QAM 802 11b CCK 11 5 5 Mbps DQPSK 2 Mbps DBPSK 11 Mbps 802 11a g 64QAM 54 48 Mbps 16QAM 36 24 Mbps QPSK 18 12 Mbps BPSK 9 6 Mbps Operating Channels central frequency US 2 412 to 2 462 GHz 11 channels 5 18 to 5 24 GHz 4 channels EU 2 412 to 2 472 GHz 13 channels 5 18 to 5 24 GHz 4 channels JP 2 412 to 2 472 GHz 13 channels ...

Page 13: ...P UDP RADIUS SNMP PPPoE DHCP Interface Default Antennas 2 dual band omni directional antennas 2 dBi RP SMA male Connector for External Antennas RP SMA female RJ45 Ports 1 10 100BaseT X auto negotiation speed F H duplex mode and auto MDI MDI X connection Console Port RS 232 RJ45 type Reset Present LED Indicators PWR1 PWR2 PoE discontinued starting with HW Rev 2 0 0 FAULT STATE signal strength CLIEN...

Page 14: ...ion 2 ATEX Zone 2 EMC EN 301 489 1 17 FCC Part 15 Subpart B EN 55022 55024 Radio EN 300 328 EN 301 893 TELEC FCC ID SLE WAPA003 Note Please check Moxa s website for the most up to date certification status Reliability MTBF 392 209 hrs Warranty Warranty Period 5 years Details See www moxa com support warranty aspx ATTENTION The AWK 3121 is NOT a portable mobile device and should be located at least...

Page 15: ... flexibility either the MAIN antenna or the AUX antenna may be selected for use Make sure the antenna connection matches the antennas configured in the AWK 3121 web interface To protect the connectors and RF module all radio ports should be terminated by either an antenna or a terminator We strongly recommend using resistive terminators for terminating the unused antenna ports ATTENTION For EXPLOS...