![Movacolor MC18-Micro Manual Download Page 13](http://html.mh-extra.com/html/movacolor/mc18-micro/mc18-micro_manual_1841085013.webp)
13
MC18-Micro manual
Tacho function
The tacho function is available in configuration 4 & 6.
This function can be used with extrusion when it is necessary that the dosing rate is automatically adjusted
to the extruder speed. In tacho mode an input voltage is coupled to a dosing speed setting. If the extruder
speed changes, the tacho input voltage and speed of the dosing unit will change accordingly.
A linear correlation between extruder speed (tacho input signal) and the needed dosing speed is assumed.
See graph.
Method 1, with a running extruder:
Press
to make the tacho function active. The display will show a numerical value that represents the
current voltage of the tacho input signal. When
is pressed the current voltage (P1 in the graph) is
coupled to the set speed (P2 in the graph).
Method 2, no running extruder (recommended to disconnect the tacho signal)
Press
to make the tacho function active. The display will show a numerical value that represents the
current voltage setting of the tacho function. Use
to set the required voltage. When
is
pressed the set value is stored (P1 in the graph).
Press
to enter the speed related to the previous set tacho voltage. The display will show the last entered
set speed (P2 in the graph). Use
to set the required speed.
When
is pressed the set value is stored (P2 in the graph).
During production, the speed (P2) can be changed. The new speed is coupled to the previous stored voltage
and the graph will change accordingly.
Tacho input voltage (VDC)
S
p
e
e
d
(
R
P
M)
Tacho graph
(Example)