![Movacolor MC18-Micro Manual Download Page 11](http://html.mh-extra.com/html/movacolor/mc18-micro/mc18-micro_manual_1841085011.webp)
11
MC18-Micro manual
7
Operation
The Interface
General
Connect motor before switching on the controller
All changes
have to be entered
to acknowledge.
A blinking value means the changed data is not entered.
To cancel a changed value, press the specific function button (
or
) again.
Most functions have a designated key and a LED on the interface. When a function is activated the LED of
that key/function will light up.
All functions except the test
function can be activated when the unit is started.
(depending on the chosen configuration.)
Only one of the following functions
,
, can be active at the same time. This means no other function
can be activated before the active function is deactivated
The unit can be set to different configurations, see paragraph 7.3 and 7.4
Start unit
Stop unit
Enter value
Run test
Input LED
Input LED is lighted when
input signal is made.
Alarm LED
Set hopper loader
Set dosing speed
[RPM]
Set dosing time
[sec.]
Increase / Decrease
value
-
Start LED
blinking:
Motor Standby / waiting on start signal.
- Start LED
lighted continuously:
Motor is running.
Set Tacho voltage
[VDC]