19
Installation manual Infix ProLine
5.4 Installing the adapter (portrait installation)
Mounting steps:
• For orientation: Mark the position of the roof battens on
the corrugated metal sheet by using a chalk line.
• Screw the portrait adapters at the points specified in
the planning (see chapter 4, „Planning the module
field“) with two 6.5 x 65 mm sheet metal screws each
onto the roof batten lying directly underneath. Use the
corresponding drill holes in the adapter.
• Install the two parts of the portrait adapters in the
module field precisely aligned above each other.
• For mounting on the lateral edges, the perforated rail
can be slid sideways up to 50 mm beyond the basis to
ensure a clean transition between roof and module
field.
Attention:
For portrait installation, the lateral flashings must be
installed before fixing the outer adapters (see point 5.5
„Installing the lateral flashings“). Ensure professional
potential equalisation of the metal surface without
damaging the leak tightness.
Material damage
Walking on the corrugated sheets
can cause dents or tears.
• Do not walk or stand on the
corrugated sheets.
• We recommend the use of a
roofer‘s ladder.
CAUTION
Material damage
Screws that are not attached in
the centre of the roof batten may
rip out.
• Position all screws in the centre of
the battens.
CAUTION
5.4-1 Portrait adapter
1.
Sheet metal screws, 6.5 x 65 mm (self-drilling)
2.
Portrait adapter (two-part)
2
1