WARNING!
ELECTRICAL SHOCK HAZARD
Improper connection of the equipment-grounding conductor can result in a risk of electrical
shock. Check with a qualified electrician or service person if you are unsure if an outlet is
properly grounded. DO NOT modify the plug provided with the appliance to fit an outlet, have a proper
outlet installed by a qualified electrician.
Mains power connection
The following should be observed when connecting the high pressure washer to the
electric installation:
_ The electric installation shall be made by a certified electrician and comply with IEC-364.
_ It is recommended that the electric supply to this appliance should include either a residual current
device that will interrupt the supply if the leakage current to earth exceeds 30 mA for 30 ms.
IMPORTANT! Only use water without any impurities.
If there is a risk of running sands in the inlet water (i.e. from your own well), an additional filter
should be mounted.
Safety devices
_
The unload valve can reduce pressure if it exceeds pre-set values. The spray gun features a locking
device. When the pawl is activated, the spray gun cannot be operated.
Thermal sensor:
A thermal sensor protects the motor against overloading. The machine will restart after a few
minutes when the thermal sensor has cooled.