background image

Ca306_01d_oi_e.doc / Apr-16 

 

Page 3 / 10 

1.

 

Safety Instructions and Responsibility  

1.1.

 

General Safety Instructions 

This operation manual is a significant component of the unit and includes important rules and 
hints about the installation, function and usage. Non-observance can result in damage and/or 
impairment of the functions to the unit or the machine or even in injury to persons using the 
equipment!  

 

Please read the following instructions carefully before operating the device and observe all 
safety and warning instructions! Keep the manual for later use.  

 

A pertinent qualification of the respective staff is a fundamental requirement in order to use 
these manual. The unit must be installed, connected and put into operation by a qualified 
electrician. 

 

Liability exclusion: The manufacturer is not liable for personal injury and/or damage to property 
and for consequential damage, due to incorrect handling, installation and operation. Further 
claims, due to errors in the operation manual as well as misinterpretations are excluded from 
liability. 

 

In addition the manufacturer reserve the right to modify the hardware, software or operation 
manual at any time and without prior notice. Therefore, there might be minor differences 
between the unit and the descriptions in operation manual. 

 

The raiser respectively positioner is exclusively responsible for the safety of the system and 
equipment where the unit will be integrated.  

 

During installation or maintenance all general and also all country- and application-specific 
safety rules and standards must be observed.  

 

If the device is used in processes, where a failure or faulty operation could damage the system 
or injure persons, appropriate precautions to avoid such consequences must be taken. 
 

1.2.

 

Use according to the intended purpose 

The unit is intended exclusively for use in industrial machines, constructions and systems. Non-
conforming usage does not correspond to the provisions and lies within the sole responsibility 
of the user. The manufacturer is not liable for damages which has arisen through unsuitable 
and improper use.  

 

Please note that device may only be installed in proper form and used in a technically perfect 
condition (in accordance to the Technical Specifications, see chapter 

10

).  

 

The device is not suitable for operation in explosion-proof areas or areas which are excluded by 
the EN 61010-1 standard. 
 

Summary of Contents for CA306

Page 1: ...a simple data preset unit with a BCD coded thumbwheel switch The unit allows an easy remote setting of single parameters e g speed setting of a drive via fieldbus By pressing the ENTER button the actual BCD setting will be transmitted to the selected register of the target unit as SDO Service Data Object For data transmission as PDO Process Data Object according to CiA DS 301 our alternative versi...

Page 2: ...tion usage or publication in other electronic and printed media as well as in the internet requires prior written authorization by motrona GmbH Table of Contents 1 Safety Instructions and Responsibility 3 1 1 General Safety Instructions 3 1 2 Use according to the intended purpose 3 1 3 Installation 4 1 4 Cleaning Maintenance and Service Notes 4 2 Introduction 5 3 Block diagram 5 4 Connections 6 5 ...

Page 3: ...he right to modify the hardware software or operation manual at any time and without prior notice Therefore there might be minor differences between the unit and the descriptions in operation manual The raiser respectively positioner is exclusively responsible for the safety of the system and equipment where the unit will be integrated During installation or maintenance all general and also all co...

Page 4: ... sections for wiring are described in the Technical Specifications see chapter 10 Before first start up it must be ensured that all connections and wires are firmly seated and secured in the screw terminals All inclusively unused terminals must be fastened by turning the relevant screws clockwise up to the stop Overvoltages at the connections must be limited to values in accordance to the overvolt...

Page 5: ... Option VZ000 the unit is supplied as version with 5 digits sign preset range 99 999 99 999 Both versions are suitable for communication on the CANopen parameter channel accessing adjustable register codes of a network participant For operation on the process data level the special PDO version CA307 is available 3 Block diagram 1 2 3 4 1 2 3 4 5 6 7 8 LED ENTER Prozessor and CAN controller Potenti...

Page 6: ...the supply voltage 60 50 40 30 20 10 10 20 30 40 mA Volt The following cables are recommended for CAN communication depending on the cable length Up to 300 meters Cable type LIYCY 2 x 2 x 0 5 mm twisted and screened Resistance 40 km Capacity 130 nF km More than 300 meters Cable type CYPIMF 2 x 2 x 0 5 mm twisted and screened Resistance 40 km Capacity 60 nF km Please use the leads like shown Pair 1...

Page 7: ...5 Setting of the network Baud rate and sign Depending on the Baud rate the following maximum cable length must not be exceeded maximum cable length Baud rate kbit s 50 125 250 500 1000 Cable length m 1000 550 250 110 25 Setting the baud rate uses positions 1 to 3 of the 4 position DIL switch on the rear 4 1 2 3 1 2 3 4 5 6 7 8 GND G C C 0 0 0 1 0 0 0 1 0 1 1 1 1 1 1 1 1 1 1 0 0 0 0 0 Baud Baud Bau...

Page 8: ...ter power down by transmitting Store EEPROM to Code C003 Slider 7 and 8 determine the register codes to be accessed in the target unit Codes shown in subsequent list refer to LENZE series 9300 drives Other code classifications are possible at any time Important note All DIL switch settings are only read upon initialization and changes during normal operation will not be recognized After change of ...

Page 9: ...n be reset by pressing the Enter button To reset Error 1 it is necessary to switch off the unit and power up again 8 Transmission details The unit transmits the data by SDO Service Data Object Write Request and awaits a corresponding Write Response within the next 2 5sec Timeout It operates similar to a CANopen master But it is no CANopen master No other CANopen communication objects are supported...

Page 10: ...20 50 125 250 500 1000 kbit s BCD switch Preset range 0 999 999 standard 99 999 99 999 Option VZ000 Housing Material Mounting Dimensions Protection class Weight plastic panel outer dimensions w x h x d 96 x 48 x 120 mm 3 78 x 1 89 x 4 72 inch cut out w x h 92 x 43 mm 3 62 x 1 69 inch front IP 40 rear IP20 IP65 is available as an option approx 250 g Temperature range Operation Storage 0 C 45 C 32 1...

Reviews: