1.3.

 

Installation 

The device is only allowed to be installed and operated within the permissible temperature 
range. Please ensure an adequate ventilation and avoid all direct contact between the device 
and hot or aggressive gases and liquids.  

 

Before installation or maintenance, the unit must be disconnected from all voltage-sources. 
Further it must be ensured that no danger can arise by touching the disconnected voltage-
sources.

 

 

Devices which are supplied by AC-voltages, must be connected exclusively by switches, 
respectively circuit-breakers with the low voltage network. The switch or circuit-breaker must 
be placed as near as possible to the device and further indicated as separator. 

 

Incoming as well as outgoing wires and wires for extra low voltages (ELV) must be separated 
from dangerous electrical cables (SELV circuits) by using a double resp. increased isolation. 

 

All selected wires and isolations must be conform to the provided voltage- and temperature-
ranges. Further all country- and application-specific standards, which are relevant for structure, 
form and quality of the wires, must be ensured. Indications about the permissible wire cross-
sections for wiring are described in the Technical Specifications (see chapter 

6

).  

 

Before first start-up it must be ensured that all connections and wires are firmly seated and 
secured in the screw terminals. All (inclusively unused) terminals must be fastened by turning 
the relevant screws clockwise up to the stop.  

 

Overvoltages at the connections must be limited to values in accordance to the overvoltage 
category II.  

 

For placement, wiring, environmental conditions as well as shielding and earthing/grounding of 
the supply lines the general standards of industrial automation industry and the specific 
shielding instructions of the manufacturer are valid.  

 

Please find all respective hints and rules on 

www.motrona.com/download.html   

--> “[General EMC Rules for Wiring, Screening and Earthing]”. 
 

1.4.

 

Cleaning, Maintenance and Service Notes 

To clean the front of the unit please use only a slightly damp (not wet!), soft cloth. For the rear 
no cleaning is necessary. For an unscheduled, individual cleaning of the rear the maintenance 
staff or assembler is self-responsible.  

 

During normal operation no maintenance is necessary. In case of unexpected problems, failures 
or malfunctions the device must be shipped for back to the manufacturer for checking, 
adjustment and reparation (if necessary). Unauthorized opening and repairing can have 
negative effects or failures to the protection-measures of the unit.   
 

Summary of Contents for AX020

Page 1: ...res Small housing dimensions of 48 x 24 mm 1 890 x 0 945 Bright LED display 6 decades 8mm 0 315 Add on frame for 50 x 25 mm 1 969 x 0 984 Analog inputs 0 to 10 V 2 to 10 V 0 to 20 mA and 4 to 20 mA Display range from 19 999 up to 99 999 Adjustable scaling factor 10 to 30 volts DC supply Latch input to freeze the display Protection class IP65 on front Minimum Maximum memory Easy to set up by menu s...

Page 2: ...in the internet requires prior written authorization by motrona GmbH Table of Contents 1 Safety Instructions and Responsibility 3 1 1 General Safety Instructions 3 1 2 Use according to the intended purpose 3 1 3 Installation 4 1 4 Cleaning Maintenance and Service Notes 4 2 Operation of the front keys 5 3 Operational parameters 6 3 1 Input range 6 3 2 Maximum value record 6 3 3 Minimum value record...

Page 3: ...he right to modify the hardware software or operation manual at any time and without prior notice Therefore there might be minor differences between the unit and the descriptions in operation manual The raiser respectively positioner is exclusively responsible for the safety of the system and equipment where the unit will be integrated During installation or maintenance all general and also all co...

Page 4: ...s sections for wiring are described in the Technical Specifications see chapter 6 Before first start up it must be ensured that all connections and wires are firmly seated and secured in the screw terminals All inclusively unused terminals must be fastened by turning the relevant screws clockwise up to the stop Overvoltages at the connections must be limited to values in accordance to the overvolt...

Page 5: ...in a cycle of two seconds Press the key on the right to increment the actual set value to next For numeric entries use the left key to select the decade and the right key to scroll the value To continue to the next parameter keep the left key down while you press the right key When you have reached the item Endpro you get the choice Yes this will store your entries to the unit and switch to normal...

Page 6: ...record on Right front key scrolls display between Act Min and Max no Maximum record off Skips next parameter rMAX YES Red key sets maximum value to the actual value no Maximum Reset disabled 3 3 Minimum value record Min YES Minimum record on Right front key scrolls display between Act Min and Max no Minimum record off Skips next parameter rMin YES Red key sets minimum value to the actual value no ...

Page 7: ...999 Sets the display value as desired with a 0V 0mA or 2V 4mA input signal 999 99 3 7 Maximum input signal High with 4 20mA or 2 10V range only 04 000 Unit shows Hi when input voltage or current gets higher than this setting 20 000 3 8 Display value with highest input signal Hi diS 199 99 Setting range 19 999 99 999 Sets the display value as desired with a 10V or 20mA input signal 999 99 3 9 End o...

Page 8: ... active HIGH 10 30V 0 20mA 4 20mA 1 2 3 4 5 6 7 0V GND Analogue 0 10V Potential separated from GND digital power supply terminal 2 5 Delivery includes Panel mounting clip Bezel for screw mount with panel cut out 50 x 25mm Bezel for clip mount with panel cut out 50 x 25mm Sealing 1 sheet with self adhesive stickers engineering units ...

Page 9: ...ccuracy Entire measuring range Temperature drift Measuring rate 0 1 1 Digit at 20 C 68 F ambient temperature 70 ppm K 2 measurements per second Display Type Digit height Range 6 digit LED red 8 mm 0 3149 inch 19999 99999 Housing Material Mounting Dimensions Miscellaneous Protection class Weight plastic panel cut out 45 x 22 mm 1 772 x 0 866 inch w x h outer dimensions 48 x 24 x 59 mm resp 1 889 x ...

Page 10: ...0 0 157 6 5 0 256 59 0 2 323 22 x45 48 0 1 890 24 0 945 22 2 0 3 45 0 0 6 1 772 0 024 0 874 0 012 max 0 76 25 0 x 50 0 53 0 2 087 26 0 1 024 1 0 0 039 4 0 0 157 25 0 0 5 50 0 0 6 0 984 x 1 969 1 969 0 024 0 984 0 020 56 0 2 205 32 0 1 260 M3 40 0 1 575 32 0 0 1 25 0 x 50 0 1 0 0 039 4 0 0 157 0 984 x 1 969 25 0 0 5 0 984 0 020 50 0 0 6 1 969 0 024 1 260 0 004 M3 A Senkung Af3 DIN 74 Counterbore Af...

Reviews: