Item
EM16
Control Mode
V/F Control, Vector Control
Other protection
features
Protection for overheating of heat sink,The carrier
frequency decreasing with the temperature
function,fault output,reverse prohibit,prohibit for
direct start after power up and error
recovery ,parameter lock up
All frames include brake transistor
Communication control
Standard built-in RS485 communication (Modbus),
One to one or One to many control.
Environment
Operating temperature
-10~50
℃
(Note1)
Storage temperature
-20~60
℃
Humidity
95% RH or less (no condensation)
(Compliance with
IEC 60068 - 2-78)
Shock
20Hz or less 1G(9.8m/s²)20~50Hz 0.6G(5.88m/s²)
(
Compliance with IEC 60068 - 2-6)
Protection class
IP20/NEMA1/IP66/NEMA4X ( Depending on models)
Note1:
IP20 type:
–10 ~ 50
℃
(without stick on type dust cover.)
–10 ~40
℃
(with stick on type dust cover.)
IP66 type: –10 ~ 50℃