This guide is provided as a help and not a total solution for every installation.
Common sense and concern for customers equipment will make for a good installation.
19
Use a plastic sleeve around cables at the hole if sharp edges can cut through the cables.
Run the cable through the slot on the mount.
Put a dab of Dicor under a cable clamp before you drill a hole to secure the clamp. After it is screwed in, cover the rest of
the screw with Dicor.
Cable ties at
these locations
will keep the
cables from
chaffing.
Use of Split Loom (Hi Temp)
is highly recommended for
the “Professional” install.
Recommended