COMPLETE:
!
The COMPLETE light will turn on at end of service or when the STOP button is pressed during the service. The
unit will automatically revert to bypass mode.
ENGINE START/ON:
!
The light will flash if the engine needs to be started or if fluid flow needs increased.
!
The light will be on solid when the engine is running indicating good flow from the vehicle.
ENGINE STOP/OFF:
!
The light will flash if the engine needs to be stopped/turned off.
!
After the engine is stopped/turned off, the light will be on steady.
EMPTY WASTE:
The light will be on when the used fluid in the WASTE tank needs to be emptied. The unit will lock out all
functions until the EMPTY WASTE button is pushed allowing the waste tank to empty.
STOP:
!
Will turn off an alarm without stopping the machine when an alarm sounds during the CHANGE FLUID mode
(when pushed only once).
!
Will stop the pump and revert the system to bypass mode and clear the memory (with the alarm sounding) when
pushed
twice
in succession or when pushed
without
the alarm sounding.
NOTE: If the unit needs to be stopped completely while an alarm is sounding, press the STOP button
TWICE. The first press will stop the alarm and the second press will stop the pump.