Component Temperature Measurement
http://www.motorola.com/computer/literature
B-3
B
Figure B-1. Thermally Significant Components—Primary Side
Component Temperature Measurement
The following sections outline general temperature measurement methods.
For the specific types of measurements required for thermal evaluation of
this board, see
Preparation
We recommend 40 AWG (American wire gauge) thermocouples for all
thermal measurements. Larger gauge thermocouples can wick heat away
from the components and disturb air flowing past the board.
U9
U14
U7
U15
U10
U1