Troubleshooting
18
68P81096E17-E
09/30/05
Figure 7. Test Equipment Setup for Verifying Receiver Circuit
1.
Disconnect antenna cable from
N-type connector on station.
2.
Connect an N-to-N type cable between
the station receive input and RF In / Out
connector on R2001.
3.
Connect service speaker to
speaker connector on
Station Control Module.
Motorola R2001
Communications
Analyzer
RF In / Out
To Receive
Antenna
Station - rear
Station - front
Service
Speaker
External Speaker
Connector on SCM
Station
Receive Input
Summary of Contents for MTR2000 T5544