Troubleshooting
14
68P81096E17-E
09/30/05
Figure 6. Test Equipment Setup for Verifying Transmitter Circuitry
1.
Disconnect cable (N-type
connector) from transmitter
antenna at station.
2.
Connect an N-to-N type cable
between the station and the
inline wattmeter.
3.
Connect the inline wattmeter
to a dummy load.
4.
Connect the transmitter antenna to the
R2001 antenna input. Be sure to pull the RF
PORT SELECT knob out and select antenna
rf input.
Dummy
Load
Inline
Wattmeter
Station
Receive Input
Station
Transmit
Output
Motorola R2001
Communications
Analyzer
Antenna
RF port select knob
(pull out)
To Receive
Antenna
Station - rear
Station - front
Service
MIcrophone
5.
Remove front panel from
station, and connect
microphone to RJ-45 connector
(P5602) on front of Station
Control Module.
Microphone
Connector on SCM