TEST SETUP & TESTING
5 - 5
Power On Registration: Required
Power Off De-registration: Required
Priority Cell: Yes
Minimum Mode Service: May Be Used
Migration: Supported
System Wide Services: Normal Mode
TETRA Voice Service: Supported
Circuit Mode Data Service: Supported
(Reserved): Available
TETRA Packet Data Service: Available
Air Interface Encryption: Not Available
Advanced Link: Not Supported
14. Press “CONFIG” soft key, select “Neighbor Cell Info”.
15. Verify that the following NEIGHBOUR CELL INFO values are displayed:
Note:
The displayed values are factory defaults and should not be changed.
BROADCAST: Not Supported
BROADCAST INTERVAL: 5s
NEIGHBOUR CELL CHANNEL: 3500
NEIGHBOUR CELL LOCATION AREA: 00017
NEIGHBOUR CELL IDENTIFIER: 01
SLOW RE-SELECT THRESHOLD ABOVE FAST: 10dB
FAST RE-SELECT THRESHOLD: 10dB
SLOW RE-SELECT HYSTERESIS: 10dB
FAST RE-SELECT HYSTERESIS: 10dB
16. Press “CONFIG” soft key, select “Call Timers & Trunking”.
17. Select “Transmission” for Trunking Type.
18. Select “Continuous” for Test Set Transmit Mode.