5 - 4
TEST SETUP & TESTING
Call Processing Tests
1. Talk Back
2. Call to Mobile
Duplex Test
Digital Duplex Test (Tx)
Measurement Capabilities:
Bar charts (Tx Power, Freq. Err, Vector Rms.), Spectrum Analyser, Power
Analyser, Vector Analyser, Vector Diagrams
How to Configure the IFR 3902 / IFR 2968 Setup
For
IFR 3902
, perform the following steps to configure the unit with the radio set:
1. Turn ON the IFR.
2. Press “CONFIG” soft key twice, go to “System” followed by “TETRA”. Select
“MS”.
3. Press “CONFIG” soft key twice, go to “Configure” followed by “Channel Plan”.
4. Press “SELECT” soft key then select “TETRA 380-400 ZERO”.
5. Press “CONFIG” soft key, select “System ID & Access Params”.
6. Enter “234” for Mobile Country Code (MCC), press enter.
7. Enter “2392” for Mobile Network Code (MNC), press enter.
8. Enter “1” for Base Station Color Code (BCC), press enter.
9. Enter “23” for Location Area Code (LA), press enter.
10. Enter “-110” for Min Rx Level For Access, press enter.
11. Enter “30” for Max TX Level, press enter.
12. Enter “-53” for Access Parameter, press enter.
13. Press “CONFIG” soft key, select “Base Services”.
Note:
You are entering base services setup.
The displayed values are factory defaults and should not be changed.