Line Current
This value indicated the total power consumed by the port; including power loss in the wire, in
the WallPlate, and efficiency.
Maximum power for any single line: 9 watts
Maximum power for a complete system: 200 watts
To determine the power for a single line use the following chart:
Line Current Value
Watts
Reference
255
2.58
Idle, no load or wire attached
197
4.87
195
4.91
190
5.02
185
5.13
180
5.31
175
5.38
2m wire attached, no load
170 5.49
165 5.60
162 5.71
160 5.82
155 5.93
150 6.11
145 6.25
140 6.40
135 6.58
130 6.80
125 7.02
120 7.24
115 7.45
113 7.53
112 7.64
110 7.71
105 7.93
100 8.18
95 8.47
90 8.76
85
9.13
600m wire attached, 2 x 100Mb load
80
9.45
75
9.85
70
10.29
65
10.76
60
11.27
55
11.78
50
12.36
45
13.05
40
13.64
35
14.40
30
15.53
25
16.33
20
17.49
Out of spec