59
7.7.6
Grounding the Installation
The Outdoor Unit (ODU) must be properly grounded to protect against power surges. It is the
user’s responsibility to install the equipment in accordance with Section 810 of the National
Electric Code, ANSI/NFPA No.70-1984 or Section 54 of the Canadian Electrical Code or the
National Electrical Code in the country of installation. These codes describe correct
installation procedures for grounding the outdoor unit, mast, lead-in wire and discharge unit,
size of grounding conductors and connection requirements for grounding electrodes. It is
recommended that installation of the outdoor unit be contracted to a professional installer.
See Section 10 “Lightning Protection” for recommended grounding kits”.
7.7.7
Making the ODU Connection at the PTP 600 Series Bridge PIDU Plus
The ODU is connected to the PIDU Plus by means of a concealed RJ45 connector. The RJ45
connection has been placed inside the PIDU Plus hinged cover to prevent the user from
inadvertently plugging other equipment into the ODU RJ45 socket.
Warning: Plugging other equipment into the ODU RJ45 socket may damage the equipment
due to the non-standard techniques employed to inject DC power into the 1000BaseT
connection between the PIDU Plus and the ODU. Plugging the ODU into other equipment
may damage the ODU and/or the other equipment.
Step 1: Undo the retaining screw and hinge
back the cover.
Step 2: Plug in the ODU into the PIDU Plus
Cable ensuring that it snaps home
Summary of Contents for MotoWI4 PTP 600 Series
Page 1: ...PTP 600 Series User Guide MOTOROLA POINT TO POINT WIRELESS SOLUTIONS ...
Page 2: ......
Page 20: ...18 ...
Page 87: ...85 Figure 34 VLAN Configuration Fields ...
Page 90: ...88 Figure 37 Save Configuration File Screen ...
Page 99: ...97 8 3 3 Detailed Counters Page Figure 43 Detailed Counters Page ...
Page 110: ...108 Figure 49 Fixed Frequency Operation ...
Page 165: ...163 Figure 97 Lower Grounding Configuration ...
Page 180: ...178 Figure 105 Connectorized 600 Series bridge Disarm Installation Page ...
Page 199: ...197 Figure 116 Diagrammatically Showing the E1 T1 Connections ...
Page 201: ...199 Figure 117 Typical Mast Installation with the addition of the E1 T1 cable ...
Page 204: ...202 Figure 119 Surge Arrestor ALPU ORT Connection Illustration ...
Page 211: ...209 Figure 132 64 QAM 0 92 Dual Payload Figure 133 256 QAM 0 81 Dual Payload ...