MCP750 Module Installation
http://www.motorola.com/computer/literature
1-23
1
!
Warning
To prevent injury, use extreme caution when handling, testing, and
adjusting this equipment. Dangerous voltages capable of causing death
exist.
3. Remove the filler panel from card slot 1 (system slot).
!
Caution
Avoid touching areas of integrated circuitry; static discharge can damage
these circuits
Note
The MCP750 must be installed in the CompactPCI system slot in
order to provide clocks and arbitration to the other slots. The
system slot is identified with a triangle symbol, which is marked
on the backplane. Some CompactPCI subracks may have a red
guide rail to mark the system slot.
4. Set the VIO on the backplane to either 3.3V or 5V, depending upon
your system’s signaling requirements, and ensure the backplane
does not bus J3, J4, or J5 signals.
5. Slide the MCP750 into the system slot. Grasping the top and bottom
injector handles, be sure the module is well seated in the P1 through
P5 connectors on the backplane. Do not damage or bend connector
pins. Secure the MCP750 in the chassis with the screws provided,
making good contact with the transverse mounting rails to minimize
RF emissions.
6. Replace the chassis or system cover(s), making sure that no cables
are pinched. Cable the peripherals to the panel connectors,
reconnect the system to the AC or DC power source, and turn the
equipment power on.