User Guide
Designer Reference Manual
DRM028 — Rev 0
136
User Guide
MOTOROLA
Minimal measurable current determined by hardware current sensing
[A]:
/* MUST_IF_HW_CHANGE_5: */
#define CURR_HW_MIN_A (-2.93)
Range: (-infinity,0>
CURR_HW_MAX_A
and
CURR_HW_MIN_A
must be changed
when current sensing range is different from default hardware.
Maximal limit of dc-bus current allowable for the hardware [A]:
/* MUST_IF_HW_CHANGE_6: */
#define CURR_MAX_FAULT_A 1.5
Range: <0,CURRENT_RANGE_MAX_A>
CURR_MAX_FAULT_A
determines the maximal current when the
drive fault state should be entered. So, it must be set to the maximum
current allowed for the power stage or the motor (see also
Maximal
and Minimal Current Limits Setting
)
6.5.3.5 Example of Software Customizing to Hardware
Let’s have low-voltage power stage ECLOVACBLDC modified to 42 V
(from 12 V) as described in its documentation. So, software must be
customized for hardware changes. Because of low-voltage set, the
const_cust_lv.h
must be modified
1. Maximal PWM duty cycle remains the same:
#define DUTY_PWM_MAX 0.942
2. Modified maximal measurable voltage is 55 V, so set:
#define VOLT_HW_MAX 55.0
3. Maximum limit of dc-bus voltage should be set according to motor
or application requirements, but VOLT_MAX_FAULT_V
> 42V
#define VOLT_MAX_FAULT_V 63.0
4. Board modified to 42 V has maximal measurable current
unchanged
#define CURR_HW_MAX_A 2.93
#define CURR_HW_MIN_A (-2.93)
5. Maximum limit of dc-bus current should remain unchanged or set
according to motor or application requirements:
#define CURR_MAX_FAULT_A 45.0