106
Motorola GPS Products
M12 Oncore User’s Guide Supplement
Revision 1.0 01/25/00
GPZDA (TIME AND DATE)
This command enables the GPZDA Time and Date message and determines the rate
at which the information is transmitted. The periodic rate field (yyyy) instructs the
receiver either to output this message once (polled), or to output this message at the
indicated update rate (continuously). Once the receiver is set to continuous output,
the continuous flow can be stopped by sending a one-time (polled) output request.
The receiver will output the response one final time, and then terminate any further
message outputs.
Currently, there is no mechanism to set the local zone description in the NMEA I/O
format, and the receiver operates as if the GMT offset is set to 00:00.
Default mode:
Disabled