![Motorola IMPRES 2 PMPN4350 User Manual Download Page 9](http://html.mh-extra.com/html/motorola/impres-2-pmpn4350/impres-2-pmpn4350_user-manual_241952009.webp)
7
English
Initialization
In order for the features of Motorola Solutions IMPRES batteries and
the Adaptive Charging System to be fully available, the data contained
in Motorola Solutions IMPRES batteries must be initialized by the
charger the first time it is charged. This process is indicated by a
Steady Amber
light on the charger indicator. The process is
automatic, includes an initial calibration of the battery, and begins
charging upon completion of this process. This process requires time
to initialize the battery, so the battery should be left in the charger for
approximately 12 hours or more to complete the process. Do not
remove the battery from the charger until the
Steady Green
light is on.
Calibration Switch
The charger is equipped with a switch on the bottom of the unit that
can be utilized to manually terminate the calibration process (as a
systemic, on-going use-case). However, the charger continues to
provide an indication that the battery needs to be calibrated.
Calibration
Required
Alternating Amber/
Green (Initial Charge)
Battery requires calibration but
Calibration is disabled in charger.
Note: The battery will continue to
charge normally (
Blinking
Green
) if it is not removed
after 5 seconds.
Alternating Amber/
Green (End of
Charge)
Battery requires calibration but
Calibration is disabled in charger.
Note: Instead of
Steady Green
, the
indicator will lights
Alternate
Amber/Green
to indicate that
the battery is fully charged.
Table 1:
IMPRES Battery Charging Indicators (Cont.)
Status
LED Status
Comments
MN004263A01.book Page 7 Friday, July 2, 2021 4:23 PM