3 - 4
FX Series RFID Readers Integrator Guide
Direct Mounting (Without the Mounting Plate)
To mount the unit without using the mounting bracket:
1.
Use the mounting bracket as a template to locate the holes, or locate and mark the holes on 4 3/16” centers,
+/- 1/32”.
2.
For wood surfaces, drill two 1/8" diameter by 7/8" deep holes on 4.192" centers. For drywall/masonry surfaces,
drill two 3/16" diameter by 7/8" deep (min) holes on 4.192" centers and install using the provided anchors.
3.
Position the reader with the key-slot holes over the mounting screws and gently slide the reader down to lock
into place.
4.
Adjust the screw head height to assure a snug fit. Or if the screws are accessible from the back, use machine
screws with a lock washer/nut and tighten the nut (from the back) to secure the reader.
Connecting Antennas
To connect the antennas to the reader (see
):
1.
Attach the antenna reverse TNC connector to an antenna port.
2.
Repeat Step 1 to connect the remaining antennas to the reader.
3.
Secure the cable using wire ties. Do not bend the cable.
CAUTION
Not using the mounting plate can result in a read performance issue at elevated temperatures.
Also, if not using the mounting plate, secure the reader to prevent it from coming off of the mounting
screws.
WARNING
!
When installing the antenna ensure a minimum separation distance of 9.1 in (23 cm)
between the antennas and all persons
.
CAUTION
Power off the reader before connecting antennas. See
Powering the Reader on page 3-5
. Never
disconnect the antennas while the reader is powered on or reading tags. This can damage the reader.
CAUTION
Do not turn on the antenna ports from a host when the antennas are not connected.
CAUTION
Maximum antenna gain (including any cable loss) cannot exceed 6 dBiL.
CAUTION
For installations where the antennas are mounted externally to the building, the screen of the coaxial
cable must be connected to earth (grounded) at the entrance to the building. This should be done in
accordance with applicable national electrical installation codes. In the U.S., this is required by Section
820.93 of the National Electrical Code, ANSI/NFPA 70.
Table 3-1
Antenna Gain and Radiated Power
FX Series
US
EU
Max Conducted RF Power
+ 30dBm
+29.2dBm
Max Antenna Gain Allowed (including cable loss)
+ 6dBiL
+ 6dBiL
Max Radiated Power Allowed
4W EIRP
2W ERP
Summary of Contents for FX7400 Series
Page 1: ...FX Series RFID Readers Integrator Guide ...
Page 2: ......
Page 3: ...FX Series RFID Readers Integrator Guide 72E 122490 01 Revision 2 August 2009 ...
Page 6: ...iv FX Series RFID readers Integrator Guide ...
Page 14: ...xii FX Series RFID Readers Integrator Guide ...
Page 22: ...1 8 FX Series RFID Readers Integrator Guide ...
Page 38: ...3 8 FX Series RFID Readers Integrator Guide ...
Page 67: ...Administrator Console 4 29 Figure 4 27 FTP FTPS Based Firmware Update Window ...
Page 72: ...4 34 FX Series RFID Readers Integrator Guide ...
Page 82: ...5 10 FX Series RFID Readers Integrator Guide ...
Page 88: ...6 6 FX Series RFID Readers Integrator Guide ...
Page 102: ...C 2 FX Series RFID Readers Integrator Guide ...
Page 110: ...D 8 FX Series RFID Readers Integrator Guide ...
Page 114: ...Index 4 FX Series RFID Readers Integrator Guide ...
Page 115: ......