background image

 

 

FlexPass OFR100                                                             

 

K02000-000                               - 6 -                               06/29/01 

 

7. Wire Color Coded & Wiring

 

I/O Port Name 

 

Signal Name   

Color Coded 

POWER 
Power (DC +5V ~ +12V) 

VDC(+) 

 

Red wire 

Power 

(Ground) 

 VDC(-)(GND) 

 Black 

wire 

 
INPUT 
Beeper 

control 

  

Beeper 

  

Blue 

wire 

LED 

control 

 

  

LED 

  

Brown 

wire 

 
OUTPUT(Wiegand Format) 
Wiegand 

Data-0 

 Data-0 

  Green 

wire 

Wiegand 

Data-1 

 Data-1 

  White 

wire 

 

OUTPUT(ABA Track II Format) 
ABA(Card 

Present) 

 CP 

  Orange 

wire 

ABA(Clock) 

  CLK 

  White 

wire 

ABA(Data) 

  Data 

  Green 

wire 

 
 

8. Wire Connection to a Host/Controller

 

 
 

 

 

 

 

 

 

 

 

 

Summary of Contents for FlexPass OFR100

Page 1: ...FlexPass OFR100 K02000 000 1 06 29 01 OPERATING AND INSTALLATION MANUAL FlexPass OFR100 Open Format Reader ...

Page 2: ...ions 3 2 Product Description 3 3 Features 4 4 Identifying Supplied Parts 4 5 Specification 4 6 Installation 5 7 Wire Color Coded Wiring 6 8 Wire Connection to A Host Controller 6 9 Wire Connection to SDC1000 7 10 Operation 7 11 FCC Registration Information 8 12 Warranty and Service 8 ...

Page 3: ...ugh the cabinet slots as they may touch voltage points or short out parts that could result in fire or electric shock Never spill liquid of any kind on the product 7 To reduce the risk of electric shock do not disassemble this product by yourself but take it to qualified service whenever service or repair is required 8 Unplug this product from the Direct Current DC power source and refer to qualif...

Page 4: ...tor Easy Mounting to a single gang box 4 Identifying supplied parts Please unpack and check the contents of the box Reader Module OFR100 Bezel Manual 1 ea 1 ea 1 ea 5 Specification Read Range Time Up to 4 10cm 300ms with Motorola FlexPass ASC 121T card and minimum read range 3 7 5cm Input Voltage Current DC 5V 12V 120mA at standby max 150mA Output Format 26 bit Wiegand or ABA Track II Magstripe Ex...

Page 5: ... top hole If you have installed an electric gang box then skip this step and go to step 6 2 6 2 Put reader cable into the center hole and install the reader module by using two 6 32 or M3 screws Not included 6 3 Put bezel on to the reader module then push bezel until you hear the locking sound 6 4 To detach the bezel hold both sides of the bezel push the bezel to the bottom and pull the bezel forw...

Page 6: ...re Power Ground VDC GND Black wire INPUT Beeper control Beeper Blue wire LED control LED Brown wire OUTPUT Wiegand Format Wiegand Data 0 Data 0 Green wire Wiegand Data 1 Data 1 White wire OUTPUT ABA Track II Format ABA Card Present CP Orange wire ABA Clock CLK White wire ABA Data Data Green wire 8 Wire Connection to a Host Controller ...

Page 7: ...LED will change color to Red again for the next reading 10 3 LED Control To change the LED colors you may connect the LED Control Input Brown wire to ground and the Green LED will turn on indicating that the reader is in standby mode Present proximity card and the LED will change color to Red then Green again for the next reading 10 4 Beeper Control In normal operation the reader generates one bee...

Page 8: ...his equipment does cause harmful interference to radio or television reception which can be determined by turning the radio or television off and on the user is encouraged to try to correct interference by one or more of the following measures 1 Reorient or relocate the receiving antenna 2 Increase the separation between the equipment and receiver 3 Connect the equipment into an outlet on another ...

Reviews: