MTS 2 and MTS 4 Installation, Con
fi
guration and Basic Service Manual
Surge Arrestors
Surge Arrestors
Please refer to
"Surge Arrestors and Suppliers"
in
Appendix A, "Field Replaceable
for more information.
Lightning arrestors should be installed to transport lightning strikes away from the equipment.
Install a lightning rod on a tower leg other than the leg to which you mount the antenna.
Power Panel
Motorola recommends that all sites where an MTS will be installed use a standardized power panel
including circuit breaker layout. Vacant space should be left to allow for future requirements.
User Alarms, Control Outputs, and Door Alarm
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
The MTS in all con
fi
gurations has the following alarm inputs and control outputs:
•
15 x 12 V opto-isolated alarm inputs - available on the junction panel
◦
Alarm inputs and Alarm ground are
fl
oating
•
2 x Form A relay outputs with Common and Normally Open contacts -
available on the junction panel
•
DOOR alarm - connected to the Site Controller
All 15 alarm inputs and Door alarm are using the same Alarm Ground. All these alarms
and controls are connected directly to the Site Controller (SC).
The Expansion Cabinet only offers the Door alarm feature.
For detailed information refer to
in
and
"User Alarms/Controls, X.21, RGPS, and GPS Cabling"
in
Chapter 5, "Interconnection and Internal Cabling"
.
.
See
for more detailed description of User Alarms input structure.
6802800U74-N September 2009
3-21
Summary of Contents for DIMETRA MTS 2
Page 4: ...This page intentionally left blank ...
Page 28: ...List of Procedures This page intentionally left blank xxii 6802800U74 N September 2009 ...
Page 30: ...List of Processes This page intentionally left blank xxiv 6802800U74 N September 2009 ...
Page 486: ...This page intentionally left blank A 10 6802800U74 N September 2009 ...
Page 492: ...This page intentionally left blank B 6 6802800U74 N September 2009 ...
Page 496: ...This page intentionally left blank C 4 6802800U74 N September 2009 ...