68009328001-A
December, 2009
Radio Alignment Procedures:
Transmitter Alignment Options
5-3
5.3.1
Initial Test Equipment Control Settings
The initial test equipment control settings are listed in
Table 5-1
.
5.4
Transmitter Alignment Options
5.4.1
Reference Oscillator Warp
This is an important operation which affects all deviation values such as
DTMF, MDC1200 Signaling
etc. The frequency will drift if not warped properly. Perform this operation prior to all other transmit
tuning operations in order to
minimize heating
and because of the
impact of warp on signaling
operations
.
Table 5-1. Initial Equipment Control Settings
Service Monitor
Test Set
Power Supply
Monitor Mode: Power Monitor
Speaker set: A
Voltage: 13.2 Vdc
RF Attenuation: -70
Speaker/load:
Speaker
DC on/standby:
Standby
AM, CW, FM: FM
PTT: OFF
Volt Range: 20 V
Oscilloscope Source: Mod
Oscilloscope Horizontal: 10 mSec/Div
Oscilloscope Vertical: 2.5 kHz/Div
Oscilloscope Trigger: Auto
Monitor Image: Hi
Monitor BW: Nar
Monitor Squelch: mid CW
Monitor Volume: 1/4 CW
Current: 20 A
Note: When checking the RF power output of the radio with a test set, always use a pad of
at least 30 dB attached to the radio end of the RF cable. This will avoid an RF
mismatch and ensure a stable RF reading that will not change with varying lengths of
connecting cable.
Figure 5-3. Reference Oscillator Warp Window
Summary of Contents for Commercial Series
Page 1: ......
Page 2: ......
Page 6: ...iv Notes ...
Page 14: ...xi Table of Contents December 2009 68009328001 A Notes ...
Page 24: ...October 2009 68009328001 A Notes 1 10 Model Charts and Test Specifications MIL Standards ...
Page 36: ...October 2009 68009328001 A Notes 4 6 Performance Checks RF Test Mode ...
Page 92: ...October 2009 68009328001 A Notes A 4 Accessories ...
Page 99: ......
Page 100: ......