B-4
Disk/Tape Controller Data
B
IOT Command Parameters for Supported
Floppy Types
The following table lists the proper IOT command parameters for
floppies used with boards such as the MVME328 and MVME162LX.
IOT Parameter
Floppy Types and Formats
DSDD5
PCXT8
PCXT9
PCXT9_3
PCAT
PS2
SHD
Sector Size
0- 128 1- 256 2- 512
3-1024 4-2048 5-4096 =
1
2
2
2
2
2
2
Block Size:
0- 128 1- 256 2- 512
3-1024 4-2048 5-4096 =
1
1
1
1
1
1
1
Sectors/Track
10
8
9
9
F
12
24
Number of Heads =
2
2
2
2
2
2
2
Number of Cylinders =
50
28
28
50
50
50
50
Precomp. Cylinder =
50
28
28
50
50
50
50
Reduced Write Current
Cylinder =
50
28
28
50
50
50
50
Step Rate Code =
0
0
0
0
0
0
0
Single/Double DATA
Density =
D
D
D
D
D
D
D
Single/Double TRACK
Density =
D
D
D
D
D
D
D
Single/Equal_in_all Track
Zero Density =
S
E
E
E
E
E
E
Slow/Fast Data Rate =
S
S
S
S
F
F
F
Other Characteristics
Number of Physical Sectors
0A00
0280
02D0
05A0
0960
0B40
1680
Summary of Contents for 700 Series
Page 2: ......
Page 3: ...700 800 Series MVME162LX Embedded Controller Installation and Use V162 7A IH1 ...
Page 48: ...1 34 Board Level Hardware Description 1 ...
Page 70: ...2 22 Hardware Preparation and Installation 2 ...
Page 138: ...A 18 Configure and Environment Commands A ...
Page 144: ...B 6 Disk Tape Controller Data B ...
Page 146: ...C 2 Network Controller Data C ...