06. COMPONENTS TEST

230V MOTOR

AUTOMATISM

8μF (230V) / 20μF (110V)

Capacitor 

1

2

3

2

COM 1

COM 2

COM

Ground Wire

Phase 2

Phase 1

Open

Close

Motor

Power Supply 1

Power Supply 2

Fig. 23

To detect if the malfunction is on the control board or on the motor is, sometimes, necessary to perform 

tests with connection directly to a 230Vac power supply.

For this, it is necessary to interpose a capacitor on the connection in order to the automatism to work 

(check the type of capacitor to be used in the product manual).

The diagram below, shows how to make that connection and how to merge the different components 

wires.

All tests must be performed by qualified personnel due to serious danger associated

with the misuse of electrical systems!

NOTES:

• To perform the tests, there is no need to remove the automatism from the place it is instal-

led, because in this way, it is possible to understand if the automatism can function properly 

connected directly to the current.

• You should use a new capacitor during this test to ensure that the problem does not lie on it.

1 • Connect the power wires to the terminal, as shown below.

2 • Connect the automatism wires in the terminal, interposing a capacitor in the

opening and closing wires.

3 • Once these connections are completed, connect to a 230Vac power outlet, depending on the motor / 

control board in test.

230V MOTOR

05. CONNECTION SCHEME

MOTOR WIRES 

|

 CONNECTIONS

Connections should be made as shown above, connecting the 6 motor wires to the appropriate inputs 

of the central and capacitor.

NOTE

: The white motor wires are connected directly to the capacitor wires!

24V MOTOR

Yellow/Green

Black

Blue

Brown

Black

Black

Wires color

Motor 1 wires

Motor 2 wires

Ground Wire

MOTOR-AP

MOTOR-COM

MOTOR-CH

Capacitor

Capacitor

Ground Wire

MOTOR-AP

MOTOR-COM

MOTOR-CH

Capacitor

Capacitor

•  

These connections correspond to an 

installation with an opening to the interior

. If the au-

tomation is installed with an opening towards the 

outside

 of the gate, you 

must swap the AP 

wire with the CH wire

 on the motor 1 and 2.

•  

If the 

motors work towards the opposite direction, swap AP with CH

.

Summary of Contents for TELICA

Page 1: ...V3 2 REV 05 2020 TELICA EN USER S AND INSTALLER S MANUAL...

Page 2: ...ystems This marking on the product or literature indicates that the product and electronic accessories eg Charger USB cable electronic material controls etc should not be disposed of as other househol...

Page 3: ...perienced in terms of usage of the product in a safe manner and who understands the risks and dangers involved Children shouldn t play with the product or opening devices to avoid the motorized door o...

Page 4: ...all safety conditions have been met In the event of tripping of circuits breakers of fuse failure locate the malfunction and solve it before resetting the circuit breaker or replacing the fuse If the...

Page 5: ...230V Power supply 24Vdc 230Vac Power 220W 380W Force 200 Nm Working frequence Intensive Use 50 Capacitor 12 5 F Protection grade IP54 Noise LpA 50dB A Thermal protection 120 C Operating temperature 2...

Page 6: ...r malfunction Fig 5 To unlock insert the unlock key into the automation front hole and turn it on clockwise 4 5 times until you feel a limit To lock Rode a chave no sentido contr rio at sentir um ob s...

Page 7: ...ion and open the door leaf to the desired position 2 Loosen A the opening ring screw and turn it B until you hear a click of the micro switch 3 Tighten the screw C of the ring to lock it in this posit...

Page 8: ...echanical stoppers in the opening and closing position of the gate If not respected components of the automation may suffer efforts for which they were not prepared and as a result will be damaged It...

Page 9: ...it is possible to understand if the automatism can function properly connected directly to the current You should use a new capacitor during this test to ensure that the problem does not lie on it 1 C...

Page 10: ...al systems NOTES To make these tests it isn t necessary to remove it from the location where it is installed be cause in this way you can understand of the automatism works properly directly connected...

Page 11: ...de which devices are with anomalies All safety devices LEDs DS in normal situations remain On All START circuits LEDs in normal situations remain Off If LEDs devices are not all On there is some secur...

Page 12: ...tor 2 Motor 2 starts closing before Motor 1 It must be applied an 8 capacitor in each motor on the opening and closing wires as explained above NOTE If any one of the motors moves in the wrong way jus...

Page 13: ...C2 230Vac 2Ah 115Vac 3Ah N0 N0 EN 09 CONNECTION SCHEME Complete opening Partial opening Flashing light 12 24VD 4W M x Transformer 230Vac or 110Vac 5 0 60Hz 120W M x Solar Panel Electric lock 12 24VDC...

Reviews: