Summary of Contents for RAP100S

Page 1: ...V3 0 REV 05 2022 RAP100S RAP100S EN USER INSTALLER MANUAL...

Page 2: ...how they can take these items for environmentally safe recycling Business users should contact their vendor and check the terms and conditions of the purchase agreement This product and its electronic...

Page 3: ...xperienced in terms of usage of the product in a safe manner and who understands the risks and dangers involved Children shouldn t play with the product or opening devices to avoid the motorized door...

Page 4: ...power and do not use it until all safety conditions have been met In the event of tripping of circuits breakers of fuse failure locate the malfunction and solve it before resetting the circuit breaker...

Page 5: ...tance load max Optical coupler NPN Voltage 55 Vdc max current 50mA Darkness current 100nA max resistance load Lines 2 3 4 e 5 Optical relay without polarity 50Vdc 0 1A electrical resistance load Input...

Page 6: ...ide and inside Do not touch the depth adjustment lever arms when replacing the cover DRILLING Attach the mounting template so the bottom edge lines up with the bottom edge of the door motor cover Dril...

Page 7: ...or to avoid cross interference Activated Activated Activated SAFETY OUTPUT REFLECTION DIAGNOSIS See the Event time table for more details on the safety output A slowly red green LED flashing indicates...

Page 8: ...at maximum when the external detection lines are enabled When connected to a door controller without a TEST input set to high When connected to a door controller with a TEST input set to low See the...

Page 9: ...2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 3 0 3 0 3 0 3 0 3 0 3 0 3 0 3 0 3 0 0 5 0 5 0 5 0 5 1 0 1 0 1 0 0 1 0 1 0 1 0 1 0 Adjust 8 degrees Adjust 0 degrees Adjust 8 degrees Adjust 0 degrees Adjust 0 degr...

Page 10: ...nd execution of entrance recognition if a person enters the detection area during the entrance recognition process it may not be performed correctly In this case the sensor will go through the process...

Page 11: ...equency indicates the type of problem AUTO DIAGNOSIS Flashing frequency LED Cause Fast Replace the sensor Slow Confirm the sensitivity potenti ometer is set and reconnect the sensor If the error persi...

Page 12: ...ode switch Z 3 to snow When the door opens or closes Orange The detection line line 1 line 2 when entrance recognition is activated is oriented very close to the door Adjust the detection depth to 3 i...