Behavior
Entrance Recognition Offline
Green
When connected to power, the green LED turns on, indicating
that the sensor is in standby mode and ready to start
detection.
Presence detection:
Presence detection on all detection lines starts 10 seconds
after switching on the sensor.
If within 10 seconds someone is walking through the detection area, about 5
seconds will be added after the person leaves the detection area, after which
presence detection will be operational.
LED
Behavior
Entrance Recognition Online
Red
When connected to power, the red LED indicates an open
relay output from the door to start the entrace recognition
process.
Green
(flashing)
The green LED flashes for 37 seconds while the "door
recognition" process is in progress. The door opens/closes.
Green
Door recognition process completed, sensor in standby
mode.
Presence detection:
during the "entrance recognition" process, the sensor's four
external lines switch from motion detection to presence detection, 10 seconds
after connecting to power. The internal detection line of "door recognition" will
be changed from motion detection to presence detection after the "entrance
recognition" process.
Allocation and execution of "entrance recognition": if a person enters the detection
area during the "entrance recognition" process, it may not be performed correctly.
In this case, the sensor will go through the process of entrance recognition in
three door activations by one person to create an accurate image of the open and
closed position of the door.
04. CONFIGURATION
04. CONFIGURATION
POWER CONNECTION AND RECOGNITION ADJUSTMENT
OPERATION CHECK
When entrance recognition is active, the sensitivity level of the internal detection line is only at
maximum when the external detection lines are enabled.
Turn off sensor power when performing the following work:
• When the floor is changed by placing a carper, etc.;
• By adjusting detection area pattern or sensor sensitivity.
POWER CONNECTION AND RECOGNITION ADJUSTMENT
See page 7B of the manual, to configure the #5
Z
After the installation is complete, execute a walk test on the detection area to verify the location. If the
detection area is not as expected, adjust it as described on page 8A or 8B increase the detection lines
using Dip switch X #3 and #4.
If the detection area still does not work as expected, you can increase the sensitivity of the sensor by
turning the potentiometer clockwise. When the sensor detects even when there is nothing in the detection
area, the sensitivity of the sensor can be lowered by turning the potentiometer counterclockwise.
Sensitivity