9A

9B

L

H

EN

EN

LED

Behavior 

Entrance Recognition Offline

Green

When connected to power, the green LED turns on, indicating 

that the sensor is in standby mode and ready to start 

detection.

Presence detection:

 Presence detection on all detection lines starts 10 seconds 

after switching on the sensor.

If within 10 seconds someone is walking through the detection area, about 5 

seconds will be added after the person leaves the detection area, after which 

presence detection will be operational.

LED

Behavior 

Entrance Recognition Online

Red

When connected to power, the red LED indicates an open 

relay output from the door to start the entrace recognition 

process. 

Green

 (flashing)

The green LED flashes for 37 seconds while the "door 

recognition" process is in progress. The door opens/closes.

Green

Door recognition process completed, sensor in standby 

mode.

Presence detection:

 during the "entrance recognition" process, the sensor's four 

external lines switch from motion detection to presence detection, 10 seconds 

after connecting to power. The internal detection line of "door recognition" will 

be changed from motion detection to presence detection after the "entrance 

recognition" process.

Allocation and execution of "entrance recognition": if a person enters the detection 

area during the "entrance recognition" process, it may not be performed correctly. 

In this case, the sensor will go through the process of entrance recognition in 

three door activations by one person to create an accurate image of the open and 

closed position of the door.

04. CONFIGURATION

04. CONFIGURATION

POWER CONNECTION AND RECOGNITION ADJUSTMENT

OPERATION CHECK

When entrance recognition is active, the sensitivity level of the internal detection line is only at 

maximum when the external detection lines are enabled.

Turn off sensor power when performing the following work:

• When the floor is changed by placing a carper, etc.;

• By adjusting detection area pattern or sensor sensitivity.

POWER CONNECTION AND RECOGNITION ADJUSTMENT

See page 7B of the manual, to configure the         #5

Z

After the installation is complete, execute a walk test on the detection area to verify the location. If the 

detection area is not as expected, adjust it as described on page 8A or 8B increase the detection lines 

using Dip switch X #3 and #4.

If the detection area still does not work as expected, you can increase the sensitivity of the sensor by 

turning the potentiometer clockwise. When the sensor detects even when there is nothing in the detection 

area, the sensitivity of the sensor can be lowered by turning the potentiometer counterclockwise.

Sensitivity

Summary of Contents for RAP100S

Page 1: ...V3 0 REV 05 2022 RAP100S RAP100S EN USER INSTALLER MANUAL...

Page 2: ...how they can take these items for environmentally safe recycling Business users should contact their vendor and check the terms and conditions of the purchase agreement This product and its electronic...

Page 3: ...xperienced in terms of usage of the product in a safe manner and who understands the risks and dangers involved Children shouldn t play with the product or opening devices to avoid the motorized door...

Page 4: ...power and do not use it until all safety conditions have been met In the event of tripping of circuits breakers of fuse failure locate the malfunction and solve it before resetting the circuit breaker...

Page 5: ...tance load max Optical coupler NPN Voltage 55 Vdc max current 50mA Darkness current 100nA max resistance load Lines 2 3 4 e 5 Optical relay without polarity 50Vdc 0 1A electrical resistance load Input...

Page 6: ...ide and inside Do not touch the depth adjustment lever arms when replacing the cover DRILLING Attach the mounting template so the bottom edge lines up with the bottom edge of the door motor cover Dril...

Page 7: ...or to avoid cross interference Activated Activated Activated SAFETY OUTPUT REFLECTION DIAGNOSIS See the Event time table for more details on the safety output A slowly red green LED flashing indicates...

Page 8: ...at maximum when the external detection lines are enabled When connected to a door controller without a TEST input set to high When connected to a door controller with a TEST input set to low See the...

Page 9: ...2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 3 0 3 0 3 0 3 0 3 0 3 0 3 0 3 0 3 0 0 5 0 5 0 5 0 5 1 0 1 0 1 0 0 1 0 1 0 1 0 1 0 Adjust 8 degrees Adjust 0 degrees Adjust 8 degrees Adjust 0 degrees Adjust 0 degr...

Page 10: ...nd execution of entrance recognition if a person enters the detection area during the entrance recognition process it may not be performed correctly In this case the sensor will go through the process...

Page 11: ...equency indicates the type of problem AUTO DIAGNOSIS Flashing frequency LED Cause Fast Replace the sensor Slow Confirm the sensitivity potenti ometer is set and reconnect the sensor If the error persi...

Page 12: ...ode switch Z 3 to snow When the door opens or closes Orange The detection line line 1 line 2 when entrance recognition is activated is oriented very close to the door Adjust the detection depth to 3 i...

Reviews: