03. CONFIGURATION

03. CONFIGURATION

EXTENDED MENU 2

LED

LED OFF

LED ON

• 

CODE

Programming Distance = OFF

Programming Distance = ON

• 

CODE PED.

Photocells test = OFF

Photocells test = ON

• 

IN.CMD.AP

Not used

• 

L. CORT.

Not used

• 

PGM. AUT.

Not used

• 

T. MOT.

PUL=Open / Close | BL = STOP

PUL=Open | BL = Close

• 

T. MOT. PED

Flashing simultaneously ON/OFF             

• 

T. PAUSA

Flashing simultaneously ON/OFF

EXTENDED MENU 1     

EXTENDED MENU 2

With the pause time programmed, it is possible to trigger the “Follow Me” option.

With this option enabled, whenever the photocells detect a some user/object passing be-
tween them, the control board triggers the closing maneuver 5 seconds after the detection. 

Activate (LED ON)/deactivate (LED OFF) function:

01.  Activate the extended menu 1 (see ACCESSING EXTENDED MENU 1 on page 5B).

02. Press SEL button once, the CODE LED will begin to flash. Press the SEL button the 

times necessary until the 

PGM AUT PED starts to flash.

03. Press SET button once to enable / disable the function.

The 

PGM AUTO LED ON indicates that the function is active and the LED OFF indicates 

that the function is deativated.

With this function active, the control board triggers the flashing lightbulb output (CN4 4 

and 5 connectors) 3 seconds before starting any opening or closing maneuver. The control 
board is supplied by the manufacturer with the step-by-step operation mode disabled. 

Activate (LED ON) / deactivate (LED OFF) function:

01.  Activate the extended menu 1 (see ACCESSING EXTENDED MENU 1 on page 5B).

02. Press SEL button once, the CODE LED will begin to flash. Press the SEL button the 

times necessary until the 

LED CODE PED starts to flash.

03. Press SET button once to enable/disable the function. The CODE PED LED ON indica-

tes that the function is active and the 

LED OFF indicates that the function is deativated.

• PGM. AUT.    | 

FOLLOW ME

• CODE PED.    | 

PRE-LIGHTBULB

• ACCESSING THE EXTENDED MENU  2

To access the options from Extended Menu 2, read the following instructions:

01. Activate the extended menu 1 (see ACCESSING EXTENDED MENU 1 on page 5B).

02. While T.MOT.PED and T.PAUSA LEDs blink alternately, return to continuously press the 

SET button for 5 seconds until they blink simultaneously.

03. The control board provides 30 seconds to select functions form the extended menu 2 

(using the 

SEL and SET buttons), and after this time it returns to the main menu.

barrier will reverse the direction of operation until reaching the limit-switch.

Operation in Step-by-Step Mode (CODE LED OFF): 

For every order sent by the transmitter / push button, the control board will behavior 

in this way: open-stop-close-stop-open(…). The control board is supplied by the manu-

facturer with the step-by-step operation mode active. 

To change the operating mode, follow these instructions:

01.  Activate the extended menu 1 (see ACCESSING EXTENDED MENU 1 on page 5B).

02. Press SEL button once, the CODE LED will begin to flash.

03. Press the SET button once to change programming.

The 

CODE LED will turn on / turn off permanently, signaling the success of operating 

mode alteration.

Activating the distance transmitter programming function:

01.  Activate the extended menu 2 (see ACCESSING EXTENDED MENU 2 on page 6B).

02. Press SEL button once, the CODE LED will begin to flash.

03. Press for 1 second the SET button and the CODE LED will light up permanently, in-

dicating the programming’s success.

Repeat the operation to restore the previous configuration.

To program a transmitter at distance, read the following instructions:

01. Press the a button from a configured transmitter for longer than 10 seconds wi-

thout releasing. The CODE LED will start to flash indicating  that the control board is in 

programming mode.

02. Press for 1 second the new transmitter button you want to program.

• CODE    | 

DISTANCE TRANSMITTER PROGRAMMING

Summary of Contents for MC15BA

Page 1: ...v3 0 REV 12 2016 EN USER INSTALLER MANUAL MC15BA...

Page 2: ...s attempt to repair or tune the automatism Must call qualified technician only The installer must have certified professional knowledge at the level of mechanical assemblies in doors and gates and con...

Page 3: ...THE CONTROL BOARD TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS CN1 CN2 04 Locking device NC Closing push button input NO 05 Common GND output 06 Safety device input NC 07 Motor s opening limit s...

Page 4: ...0 strength In each movement startup the central applies full power for 2 seconds even when it is made the force regulation for avalue than the maximum FORZA Whenever the VR1 trimmer is adjusted the co...

Page 5: ...ry until the INB CMD AP LED starts to flash 02 Press SET button once to enable disable the function The INB CMD AP LED ON indicates that the function is active and the LED OFF indicates that the funct...

Page 6: ...and SET buttons and after this time it returns to the main menu EXTENDED MENU 1 LED LED OFF LED ON CODE Step by step Inverter CODE PED Lightbulb Pr lightbulb IN CMD AP Not used L CORT Not used PGM AUT...

Page 7: ...is deativated PGM AUT FOLLOW ME CODE PED PRE LIGHTBULB ACCESSING THE EXTENDED MENU 2 To access the options from Extended Menu 2 read the following instructions 01 Activate the extended menu 1 see ACC...

Page 8: ...control board to the factory settings press the SEL and SET keys simultaneously At this time all LEDs will light up simultaneously and then will turn off indicating the reset s sucess 04 COMPONENTS TE...

Page 9: ...mittent mode indicating the error When the photocells operation is corrected the control board returns to it s normal functioning This action by the control board allows to recognize failures in accor...

Page 10: ...ge 7B 3 If the motor works the problem is from control board Pull it out and send it to our MOTORLINE technical services for diagnosis 4 If the motor doesn t work remove them from installation site an...

Page 11: ...2 3 1 2 3 4 5 V ENC DV NC COM 12 24V DV 12 24V L PE N PUL 24Vac EN 06 CONNECTION SCHEME COMPONENT CONNECTION TO THE CONTROL BOARD Flashing Light Barrier At BL you can connect a STOP switch button Eve...

Page 12: ...is based on the existing letters of the LED strip It is considered as incorrect posi tion when the letters are inverted with the light sensor on the left L SENSE Only lights up when it detects that th...

Reviews: