![Motorline professional MC15BA User& Installer'S Manual Download Page 3](http://html1.mh-extra.com/html/motorline-professional/mc15ba/mc15ba_userand-installers-manual_1838623003.webp)
2A
2B
FUSE 5X2
M
K
K
01
CN1
CN2
01 02 01 02 03 04 05 06 07
01 02 03 04 05 06 07 08 09 10 11
CN3
CN4
05
04
03
02
01
EN
EN
01 • Grounding
02 • Grounding
01 • 110V or 230V Line Input (phase)
02 • 110V or 230V Line Input (neutral)
03 • Lightbulb/magnetic lock’s output AC110V or AC230V 100W Max (neutral)
04 • Lightbulb/magnetic lock’s output AC110V or AC230V 100W Max (phase)
05 • 110V or 230V Motor’s Output – Opening
06 • 110V or 230V Motor’s Output – Common
07 • 110V or 230V Motor’s Output - Closing
01 • Photocells power supply output (24V AC 6W)
02 • Photocells power supply output (GND)
03 • Step-by-Step transmitter button or opening button input (NO)
The
MC15BA is a monophasic control board com a control system via incorporated rá-
dio, developed for the automation of electromechanical barriers.
It is possible to integrate on the central, a radio system which operates as a safety
device composed of a "Base"
RTX 2278 receiver-transmitter module (connected on the
own central) which receives a maximum of two “Sensor”
RTX 2252 receiver-transmitter,
powered by batteries, for the connection of mechanical safety bands and
resistive 8K2 Ohm, usually installed in the aluminum rod.
02. THE CONTROL BOARD
02. THE CONTROL BOARD
TECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS
CN1
CN2
04 • Locking device (NC) Closing push-button input (NO)
05 • Common GND output
06 • Safety device input (NC)
07 • Motor’s opening limit-switch input (NC)
08 • Common GND output
09 • Motor’s closing limit-switch input (NC)
10 • Antenna's common input
11 • Antenna's hot pole input
01 • + 24V DC to RGB output
02 • 0V FCHD enabled during (closed barrier) 100mA maximum capacity
03 • 0V ABRT output enabled during (Pause time) 100mA maximum capacity
04 • 0V FCH output enabled during (closure) 100mA maximum capacity
05 • 0V ABR output enabled during (opening) 100mA maximum capacity
• CONNECTOR’S DESCRIPTION
CN3
CN3
CN4
Before proceeding to the control board configuration, pay special attencion to the
following parameters in the table below in order to better understand the control board
functions:
PROGRAMMING PRE-RECOMENDATIONS
110V
230V
•
Power supply
110V AC 50-60Hz
230V AC 50-60Hz
•
Lightbulb’s output
110V AC 50Hz 500W máx.
230V AC 50Hz 500W máx.
•
RGB Lightbulb’s output
24V DC 100mA máx.
•
Motor’s output
110V AC 50-60Hz 1000 W máx. 230V AC 50-60Hz 1000 W máx.
•
Auxiliary accessories output
24V AC 6 W máx.
•
Security and BT transmitters
24V DC
•
Working temperature
-10°C a + 55°C
•
Incorporated Radio Receptor
433,92 Mhz
•
OP Transmitters
12-18 bits or Rolling Code
•
Maximum memory capacity
120 (CODE or CODE PED)
•
Control board Dimensions
108x138 mm.