background image

16.A

230V

T.MOT.

CODE L.

CODE

SET

SEL

CN1

CN2

LAMP

N

COM

F

1 2 3 4 5 6 7 8 9

FUSE FUSE

N

F

CN1

T.MO

T

CODE

SEL

SET

1

3

2

4 5 6 7

TUB20R

COM

+

-

LED 1

+

-

LED 2

MC7

MC65

▷ SCHEME OF CONNECTIONS (CONTROL BOARD MC6 AND MC7)

07

CONNECTIONS TO CONTROL BOARD

Circuit breaker 16A. not supplied

Power Supply (3x1.5mm²)

Ground wire

Blue wire

Black wire

Br

own wir

e

Blue wir

e

Black wir

e

Ground wire

Gr

ound wir

e

Black wire

Blue wire

Ground wire

Brown wire

Blue wire

Brown wire

Blue wire

Ground wire

Black wire

Blue wire

Brown wire

LEDs

Transformer 

Brown wire

Blue wire

MOTOR TUB

Summary of Contents for COFRE 260

Page 1: ...COFRE 260 VOLANTE INSTALLER AND USER S MANUAL v2 0 REV 02 2019...

Page 2: ...physical injury and material damage Keep these instructions in a safe place for future reference This product was designed and produced strictly for the use indicated in this manual Any other use not...

Page 3: ...sy assembly Allows a maximum incline of 20 TUB90M8 MT Frequency Speed Force Lift up Noise Working time Diameter Voltage Consumption Weight set 230v AC 50Hz 0 68A 2 40Kgs 45mm 8min 43dB 35Kgs 12RPM 50N...

Page 4: ...hat the metal bushings bolts are tight ened on a solid surface and resistant so there is no risk of loosening and fall of the awning Never open the casing before the installation is completed as it ma...

Page 5: ...LLATION 04 Insert metal bushings M12 in the created holes Position the wall bracket n 8 in the holes and apply the screws M12x90 with their respective washers screws washers and bushings not included...

Page 6: ...e 3 03 INSTALLATION 03 INSTALLATION INCLINATION ARMS REGULATION CEILING INSTALLATION Insert the wall brackets n 8 in casing holders n 4 and measure it A with the supports Transport this measure A to t...

Page 7: ...nut approximately 7mm so that the upper part of screw is loosened out of the arm 02 Using a hammer apply a gentle tap until the screw rises enough to be tuned Use a hex key to turn the screw to the r...

Page 8: ...ply s direct connection FABRIC REGULATION TUB MOTOR Common Blue Brown Black Ground wire 230V Power supply The motor will rotate in a particular direction To invert the direction of rotation change the...

Page 9: ...sor sun wind rain GROUP OR GENERAL CENTRALIZATION Centralization via radio through transmitter The centralization of two or more control boards via radio allows simultaneous movement of ascending or d...

Page 10: ...rapidly Send the second code opening to be memorized the LED CODE will remain ON and programmation is finished If the second code is not sent within 10 seconds from the first one the unit exits the pr...

Page 11: ...ol board the opening closing will be automatically activated after 30 minutes If poor communication continues other remote controls will keep the control board in a state of security not allowing the...

Page 12: ...tion Codes The cancellation of all codes memorized for the functioning of awning remote controls and Wireless Sensor proceed as follows press the SEL button LED CODE will flash and then press the SET...

Page 13: ...econd so it does not effort the fabric too much This inversion time is selected through the extended menu 2 in accordance with the motor installed in case of a motor 17 or 12 rotations to that the awn...

Page 14: ...g press the SEL button and CODE LED will blink At the same time send the first CODE No code Ref LED LED OFF LED ON Programmed code Motor time programmed Working Time 3 min T MOT code closing selected...

Page 15: ...r time is 3 minutes With T MOT LED OFF and the remote control programmed we can move the awning in the opening closing direction until you make the adjustment of the limit switches Follow the instruct...

Page 16: ...h quickly signaling that other memorizations are not possible 05 MC7 CONTROL BOARD 06 TROUBLESHOOTING INSTRUCTIONS FOR CONSUMERS AND SPECIALIZED TECHNICAL PROGRAMMING The awning does not stay leveled...

Page 17: ...TIONS CONTROL BOARD MC6 AND MC7 07 CONNECTIONS TO CONTROL BOARD Circuit breaker 16A not supplied Power Supply 3x1 5mm Ground wire Blue wire Black wire Brown wire Blue wire Black wire Ground wire Groun...