7. MAINTENANCE RECORD SHEET

YES       NO

Date:          

Made by:

Comples:

Remarks:

Signed  by  the  service                                               

Technician:                                                                           

(name of the service technician)

Signed by the 

client:                                                                              

Date:          

Made by:

Comples:

Remarks:

Signed  by  the  service                                               

Technician:                                                                           

YES       NO

(name of the service technician)

Signed by the 

client:                                                                              

Date:          

Made by:

Comples:

Remarks:

Signed  by  the  service                                               

Technician:                                                                           

YES       NO

(name of the service technician)

Signed by the 

client:                                                                              

Date:          

Made by:

Comples:

Remarks:

Signed  by  the  service                                               

Technician:                                                                           

YES       NO

(name of the service technician)

Signed by the 

client:                                                                              

Summary of Contents for EvoDrive+

Page 1: ...intenance manual GB EvoDrive Maintenance manual Part 4 of the Installation User and Maintenance Manual This section must be given to the Owner of the automatic door and be always available for the Maintenance technician ...

Page 2: ...pproved by them When performing ordinary or extraordinary maintenance tasks that require to stop the operation of the EvoDrive auto matic guide it is compulsory to interrupt or shut down the power supply 230V AC and proceed with diligence The EvoDrive automatic guide does not require any particular maintenance interventions except cleaning the top and bottom track rails a general door cleaning and...

Page 3: ... manual GB 2 EVODRIVE COMPONENT OVERVIEW 1 Main profile 2 Linear motor type LSMPM 3 Leaf trolleys 4 Power supply circuit 5 I O accessories control board 6 Motor driver 7 Permanent neodymium magnets 8 End stops 9 Side covers 10 Aluminium cover with brush seal ...

Page 4: ...tinuous Number of cycles 1 000 000 Adjustable parameters Opening direction right or left Biestable Mode Low energy or normal mode Opening speed Hold open time Power supply 80 264 VAC 390 VDC 47 63 Hz Universal Maximum Operatin Power 180 W Protection fuse 2 A Cable section 3x1 5 mm2 Length 2 m Power consumption In motion 60 W Max 0 2 s 180 W In stand by 4 W Motor Type Linear LSMPM Linear Synchronou...

Page 5: ...thly Verify that the final adjustment has been made see p 19 of EvoDrive installation manual Check if the operator is in Low Energy Check that no item is generating excessively friction Verify that the final adjustment has been made see p 19 of EvoDrive installation manual Verify that I O Accessories is switched ON Verify that the operator is not in open mode Verify that the sensors accessories ha...

Page 6: ...em has detected an encoder error verify that the motor has magnets during the entire journey if not restart the automatic guide and if the error persists contact your dealer indicating the error code Error 3 Code 03 blinking The system has detected a weight error verify that the leaf does not exceed 80 kg the friction of the floor guide is not excessive and the leaf can be moved manually throughou...

Page 7: ... indicating the error code Error 8 Code 08 blinking The system has detected an error in the internal non volatile memory of the electronics restart the automatic guide and if the error persists contact your dealer indicating the error code Error 10 Code o1 blinking The system has detected an obstacle when the door was opening Error 11 Code o2 blinking The system has detected an obstacle when the d...

Page 8: ...he door does not work The interior sensor led is still on when there is no detection of move ment or presence The exterior sensor led is still on when there is no detection of move ment or presence The exterior push button led is permanently on The push button is permanently blocked in push position The interior push button led is permanently on The push button is permanently blocked in push posit...

Page 9: ... of the sliding leaf suspension Yearly 50 000 Adjustment of all screws in general Yearly 50 000 Adjustment of the automatic lock if supplied Yearly 50 000 Adjustment of the gap between motor and magnets Yearly 50 000 Test of the safety sensors Yearly 50 000 Test of the activation devices radars sensors touch less switch push buttons etc Yearly 50 000 Test of the remote control battery Every 2 year...

Page 10: ...by the client Date Made by Comples Remarks Signed by the service Technician YES NO name of the service technician Signed by the client Date Made by Comples Remarks Signed by the service Technician YES NO name of the service technician Signed by the client Date Made by Comples Remarks Signed by the service Technician YES NO name of the service technician Signed by the client ...

Page 11: ... Date Made by Comples Remarks Signed by the service Technician YES NO name of the service technician Signed by the client Date Made by Comples Remarks Signed by the service Technician YES NO name of the service technician Signed by the client Date Made by Comples Remarks Signed by the service Technician YES NO name of the service technician Signed by the client ...

Page 12: ...Linear Motor Applications S L Pol Ind Santiga Pasaje Arrahona 4 Nave 1 08210 Barberà del Vallès Barcelona España Tel 34 935 624 639 Fax 34 935 737 308 E mail info motion4 eu www motion4 eu ...